Charles Austen Four DSW2 Lake Aeration Kit

SKU: TPG-AER-ET400-4DSW2
Brand

Air Pump

Charles Austen ET400, Charles Austen ETD400

Diffuser Layout

4 x DSW2 twin-disc stations

Weighted Airline

120m total (4 x 30m), 240m total (4 x 60m)

Air Pressure

ET400: 0.20 bar, ETD400: 0.15 bar

Water body size

Large lake

Four DSW2 twin-disc stations for separate bays or a wide lake. Choose the Charles Austen ET400 or ETD400 and 4 Ă— 30 m or 4 Ă— 60 m weighted airline runs. The kit includes a 4-way valved manifold, matched fittings and clips.

The ETD400 works at 0.15 bar. Send us your diffuser depths and airline lengths for a free sizing check.

Price range: £1,857.34 through £2,666.99 (inc VAT)

Available on back-order

Charles Austen Four DSW2 Lake Aeration Kit

Four twin-disc stations for wider or irregular lakes

This complete system combines a land-mounted linear air pump, self-sinking diffuser stations, weighted airline, flow control and the secure fittings needed for a properly planned large-pond or lake installation. It is best suited to wide, irregular or multi-basin lakes where four circulation points are more useful than two larger plumes.

Why this layout works

  • Four separate positions help tackle corners, lobes and multiple basins.
  • 4 independently valved branches feed eight diffuser discs across the layout.
  • Balance each station at the manifold to account for differences in hose length and water depth.

What is included

  • 1 Ă— Charles Austen air pump, ET400 or ETD400 as selected
  • 4 x DSW2 twin-disc diffuser stations
  • 1 Ă— high-flow 4-way valved manifold
  • Super-heavy weighted airline for 4 Ă— 30 m or 4 Ă— 60 m runs, as selected. The 60 m runs use pairs of 30 m reels with supplied joiners.
  • Correctly sized connectors, reducers, stainless steel hose clips and installation guidance

Spread aeration over four zones

Use this layout for wide or irregular lakes where you want a diffuser in separate bays, lobes or areas of the lake. Each branch feeds one DSW2 station with two diffuser discs. The four-way valved manifold lets you balance the routes. Check the airflow at each station during commissioning, since differences in depth and line length affect the split.

Airline: the 120 m option supplies four 30 m lines; the 240 m option supplies eight 30 m reels with the secure joiners needed for four 60 m lines. Choose by the longest actual route from the manifold to a station, including bends and the descent to the diffuser.

Choose your air pump

Use the Air Pump menu to choose the Charles Austen ET400 or ETD400. Both versions include four DSW2 twin-disc diffuser stations and the same choice of weighted airline lengths.

Pump working pressures
Pump option Working pressure
Charles Austen ET400 0.20 bar
Charles Austen ETD400 0.15 bar

Choose the pump for the pressure it will work against at your site. The depth above each diffuser and resistance along each airline run both affect the air reaching the stations. For an ETD400 sizing check, send us the diffuser depths and the measured length of each route.

ET400 and ET500 airflow compared

The chart covers the ET400 and ET500. Ask us to check your ETD400 layout using the intended diffuser depths and airline runs.

The ET400 is rated at 400 L/min at 0.20 bar in the UK 50 Hz manufacturer datasheet. The ET500 is rated at 500 L/min at the same pressure and 460 W. If 400 L/min reached the four branches evenly, each DSW2 would receive 100 L/min, or around 50 L/min per disc. Use that as a sizing check, not a promised output. For an indicative 30–60 L/min per disc, each two-disc station needs about 60–120 L/min after installation.

Charles Austen ET400 and ET500 UK pump airflow against total backpressure, with freshwater pressure equivalents rather than maximum depths.
ET400 and ET500 only. Approximate readings from the Charles Austen ET400/ET500 UK 220–240 V, 50 Hz datasheet. The curves compare the pumps; they do not predict the airflow split among four installed stations.

Water-depth equivalents are not recommended maximum depths. Fresh water adds about 0.10 bar per metre of depth. Check the full working pressure after allowing for the airline, joiners, manifold and diffuser membranes. Measure branch flow when commissioning rather than relying on equal valve settings or a pond-volume rule.

Choose the airline length

Standard: 4 x 30m super-heavy weighted airline lengths. Choose the extended option for 4 x 60m lines using eight 30m reels and secure joiners. The product selector prices the extra weighted airline and any required straight joiners automatically.

Secure each airline connection using the supplied stainless steel clips. For runs outside the listed options, add extra 30m weighted airline or ask us to check your layout.

Installation and safe start-up

  • Position the air pump on a firm, dry, ventilated base above the water level, or use a correctly rated non-return arrangement where this is impossible.
  • Use an outdoor electrical supply protected by a 30mA RCD and keep electrical connections out of the water.
  • Keep manifold and trunk connections full-bore; avoid unnecessary reductions that create back pressure.
  • Place diffuser stations level and use the valves to balance visible bubble output. Never lift a diffuser by its airline.
  • In an older, stagnant or strongly stratified pond or lake, introduce bottom aeration gradually. Rapidly mixing poor-quality deep water through the whole water column can temporarily reduce oxygen and stress fish.
  • Clean diffuser membranes and inspect airline, clips and pump filters regularly. Service the pump with the correct diaphragm and filter kit.

Compare the complete aeration kit range

See the Large Pond & Lake Aeration Kits guide, or compare another layout:

Free suitability check before you order

Send us the pond’s length and width, average and maximum depth, approximate volume, fish type and stocking level, distance from the pump to each diffuser position, and whether the main goal is fish oxygen support, circulation, de-stratification or emergency aeration. We will check the pump, diffuser count and airline layout before dispatch.

Compare ETD aeration kits for shallower installations

The ETD range provides additional pump and diffuser combinations where lower operating pressure suits the pond. Compare the diffuser positions and included airline lengths, then check the depth and route against the pump performance.

The ETD200 is rated at 200 litres per minute at 0.15 bar. The ETD150 kits share the available airflow between three diffuser heads, either across three DSW1 stations or a DSW2 and a DSW1. Compare all large pond and lake aeration kits for the full choice of layouts.


Products related to the Charles Austen Four DSW2 Lake Aeration Kit

Charles Austen Four DSW2 Lake Aeration Kit Reviews

Reviews

There are no reviews yet.

Be the first to review “Charles Austen Four DSW2 Lake Aeration Kit”