Charles Austen 120 Twin-Zone DSW1 Pond Aeration Kit
| Brand | |
|---|---|
| Air Pump | Charles Austen ET120, Charles Austen ETi120 |
| Power | 125 W, 75 W |
| Diffuser Layout | 2 x DSW1 single-disc stations |
| Weighted Airline | 30m total (2 x 15m), 60m total (2 x 30m) |
| Air Flow | 120 L/min |
| Air Pressure | 0.12 bar, 0.15 bar |
| Water body size | Large pond / small lake |
Aerate two separate parts of the pond with two DSW1 diffuser stations. Compare the ET120 and lower-power ETi120, then choose two pre-cut 15 m runs or two 30 m runs of weighted airline. Check the selector for current availability.
Price range: £545.48 through £715.98 (inc VAT)
Available on back-order
Charles Austen 120 Twin-Zone DSW1 Pond Aeration Kit
The 120 Twin-Zone kit keeps the same two independent aeration points as the 100-series layout, but gives you 120 litres per minute at the chosen pump’s published operating point. Use it where a long, offset or irregular pond calls for separate single-disc stations and the pump curve shows useful airflow at the planned depth and airline resistance. A higher nominal output is not automatically better: the two DSW1 discs still need airflow within their own working range.
Compare the standard ET120 and lower-power ETi120
Both pumps are rated at 120 litres per minute. The ET120’s rating is at 0.12 bar and the ETi120’s is at 0.15 bar. The ETi120 uses less power at its published rating. For a longer route or a deeper station, compare how much each supplies at the pressure the installation will actually create. The operating curves give more useful sizing information than the headline pump rating alone.
| Pump | Rated airflow and pressure | Published power |
|---|---|---|
| ET120 | 120 L/min at 0.12 bar | 125 W |
| ETi120 | 120 L/min at 0.15 bar | 75 W |
To read the comparison, find the total backpressure on the bottom axis and read the approximate airflow from each curve. The top axis gives freshwater equivalents for the pressure of water alone, with about 0.10 bar per metre of depth.

The depth equivalents are not recommended maximum depths. An installation adds resistance from the full length of weighted airline, bends, the manifold, fittings and the diffuser membranes. Check the combined resistance before relying on a quoted flow.
Choose 15 m or 30 m for each of the two runs
- One chosen Charles Austen 120-series pump and two independently positioned DSW1 single-disc diffuser stations.
- One two-way valve manifold, with an 18 mm inlet and two 14 mm outlets for this airline configuration.
- 30 m total: two pre-cut 15 m lengths of weighted airline, one per station.
- 60 m total: two 30 m lengths, one per station.
Use the actual path from the manifold across the bank, down into the water and around any obstacles. A 24 m bank-to-station route needs the 30 m length, even if the pond looks much narrower on a plan.
The kit includes the matched 18 mm flexible boot and clips for the AP422 manifold. On the ETi120, use the bare 18 mm pump outlet for this kit; leave the supplied 12 mm screw-in reducer off. The 14 mm manifold outlets are for the two weighted airline branches.
Set up two zones without overdriving a diffuser
At 120 L/min, an even split would put 60 L/min through each DSW1, already at the upper end of its 30–60 L/min range. A short, shallow branch can take more air than the other, and airflow can rise at lower pressure. Don’t use the pump rating as a target for each station: check both branches and keep them within the diffuser’s working range. Use the two valves for small balancing adjustments with the system running normally, and do not close both outlets with the pump running.
If both runs are short and shallow, a lower-output kit may be a better match. If the two sites are far apart, or one area needs more than a single disc, compare the other pond and lake aeration layouts. Send us the two depths and route lengths if you’d like help choosing.



Reviews
There are no reviews yet.