Remora F8 8.79kW On/Off Heat Pump with Wi-Fi for Koi Ponds and Pools
| Brand | |
|---|---|
| Rated heat output | 5–10 kW |
| Heating type | Air source heat pump |
| Wi-Fi control | Built in |
| Heating control | Fixed speed |
| Power supply | Single phase |
| Air discharge | Horizontal |
| Electrical connection | Suitable for standard 13A UK socket |
| Electrical input | Electrical input at A15/W26: 1.23 kW |
| Maximum current | 9.58 A |
| Pond Capacity | 10,000–15,000 litres |
The Remora f8 is a fixed-speed air source heat pump with Smart Life Wi-Fi control for koi ponds and swimming pools. A 5–40°C heating setpoint range supports a choice of pond temperatures. Check the performance, flow and electrical requirements below when planning your installation.
£1,290.00 (inc VAT)
Remora F8 8.79kW On/Off Heat Pump with Wi-Fi for Koi Ponds and Pools
At a glance
- Model heat-output rating: 8.79 kW
- Power supply: Single phase
- Compressor control: Fixed speed
- Air discharge: Horizontal
- Electrical connection: Suitable for standard 13A UK socket
The model rating is heat delivered to the water, not electricity consumption. Compare the test conditions and cooler-weather figures in the technical specifications below.
Controlled heating and cooling with built-in Wi-Fi
The Remora f8 is a fixed-speed air source heat pump for koi ponds and swimming pools, with Smart Life Wi-Fi control and a heating setpoint range of 5–40°C. Its published heat output is 8.79kW at 24°C air and 26°C water, falling to 6.7kW at 15°C air and 26°C water. Compare those conditions when assessing it against other models.
The on/off compressor works at a fixed operating speed, cycling in response to the controller. This is a different control arrangement from the Remora Inverter and Professional ranges. It provides another option when comparing purchase cost, heat demand and the way you intend to use the heater.
For koi keepers, the first decision is what you want the heater to achieve. Holding a covered pond at a moderate temperature during winter is a different job from warming the water earlier in spring. Use the published specifications alongside your pond’s heat requirement when choosing the model. Compare other models in our air source heat pump range, or explore the alternatives under pond heating.
Remora f8 specifications
| Heating output at A24/W26 | 8.79 kW |
|---|---|
| Heating output at A15/W26 | 6.7 kW |
| Maximum current | 9.58 A |
| Water flow range | 3–4 m³/hour |
| Net weight | 54 kg |
| Water connections | 1½ inch |
| Power supply | Single phase |
| Heating setpoints | 5–40°C |
| Operating air range | −15–43°C |
| Refrigerant | R32 |
| Wi-Fi | Smart Life app |
| Electrical input at A15/W26 | 1.23 kW |
| COP at A15/W26 | 5.45 |
| Nominal water flow | 3.78 m³/hour |
| Dimensions (L Ă— W Ă— H) | 933 Ă— 401 Ă— 657 mm |
| Published noise level at 10 metres | 29 dB |
| Supply voltage | 230 V |
Choosing it for a covered koi pond
If your aim is approximately 12°C through winter, tell us the pond volume, surface dimensions, construction, cover arrangement and location. Include any exposed filter chambers or long external pipe runs. Two ponds containing the same number of litres can lose heat at very different rates, so volume is a starting point rather than a complete sizing calculation.
The output figures above also show why the model name should not be treated as a guaranteed winter heating output. Published performance changes with the test conditions. Neither of those figures is a specific prediction for a cold night with the pond at 12°C. A winter recommendation needs to allow for the local conditions, heat loss and time spent defrosting. For a winter recommendation, provide the pond dimensions, cover details, location and target temperature so the heater can be matched to the heat loss.
For spring and autumn use, explain when you intend to start heating and the temperature you want to maintain. A heater selected for modest seasonal support may not have enough reserve for continuous winter duty or a higher target temperature. Resolve that choice before comparing purchase prices, as the most economical installation is one selected for the intended job.
Understanding on/off heating
A fixed-speed compressor does not continuously adjust its speed to match demand in the same way as an inverter. The controller starts and stops heating as necessary within its operating logic. Keep the required water circulation available and follow the manual when setting timers or coordinating the heater with other equipment.
Heating output is different from electricity consumption. Compare efficiencies at matching air and water temperatures, and do not use a warm-weather COP as a forecast for the whole winter bill. Covers, insulation and exposed pipework have a substantial effect on the heat that must be replaced.
Water flow and installation planning
Plan the water circuit so that the heater receives the specified flow. The circulating pump, pipe diameter, fittings and any bypass arrangement all affect what reaches the heat exchanger. Do not assume the pump’s advertised maximum flow is the flow through the installed heater. Include suitable isolation and service access so maintenance does not require dismantling the surrounding filtration.
Before ordering fittings, check the exact supplied union arrangement against the installation manual and the pipework already on your pond. Provide space to disconnect the water connections and to drain the equipment when necessary. A bypass can be useful for setting the heater branch flow and for servicing, but it must be arranged to suit the actual system.
Outdoor siting and electrical connection
Choose a firm, stable outdoor position that leaves the manufacturer’s required clearances around the unit. Keep the air inlet and discharge clear of close fencing, vegetation and stored equipment. Enclosing a heat pump without a designed airflow route can cause it to draw its own cooled discharge air back in, reducing its ability to collect heat.
Allow for condensate drainage as part of the installation. Water produced during normal operation needs somewhere suitable to go without creating a slippery path or collecting around the base. Leave enough access for inspection and cleaning, as well as for opening service panels.
The f8 is supplied with a 2.8m lead and UK plug. Use a suitable protected supply and have the circuit checked if its suitability is uncertain. Follow the supplied manual and keep connections appropriate for an outdoor installation.
Remote temperature control
The Smart Life app allows temperature checks and adjustments when the unit has a suitable Wi-Fi connection. Check signal coverage at the chosen location and follow the setup instructions. Local inspections remain important; remote control is not a substitute for checking circulation and equipment condition.
Daily use, monitoring and winter care
Make temperature changes gradually and monitor the pond with a suitable thermometer. App access is useful for checking settings, but it is not a substitute for inspecting water circulation, the pond and the equipment. If the heater stops, investigate the cause and follow the fault guidance before changing settings repeatedly.
Keep the air path clear and inspect the drainage route regularly. If the heater will be taken out of service during freezing conditions, follow the manual’s draining and winterisation instructions. Switching the electrical supply off alone does not remove water trapped inside the heat exchanger. An idle unit and an actively heating installation require different winter arrangements.
Choosing between heat pump types
Compare this fixed-speed model with the alternatives in our air source heat pump range. Match the controls, heating output and electrical requirements to your intended use. Our pond heating guide explains the wider selection considerations.
Installation manual and model information
Download the Remora F manual for installation, controls and fault guidance. Use the f8 column when comparing dimensions and electrical details. A24/W26 means air at 24°C and water at 26°C; A15/W26 means air at 15°C and water at 26°C. The quoted noise figure is measured at 10 metres, so it should not be compared directly with a figure measured beside another unit.
Comparing the f8 with the smaller f6
At the same A15/W26 test condition, the f8 delivers 6.7kW of heat compared with 4.7kW from the Remora f6. This is a useful comparison when the smaller unit does not meet the calculated duty. The f8 also needs more circulation: its nominal flow is 3.78m³/hour, compared with 2.63m³/hour for the f6. Check that the installed water circuit can deliver the additional flow.
The f8 cabinet measures 933 Ă— 401 Ă— 657mm and weighs 54kg. Allow for those dimensions, the required airflow clearances and a safe delivery route. Its factory-fitted lead and plug simplify connection where an appropriate supply is already available; they do not remove the need to check circuit suitability.
Supplied fittings and warranty
The UK supplier lists 1½-inch water unions, rubber feet, a winter cover, a condensate hose and elbow, and the manual with the Remora F range. Check your existing pipework before selecting any additional adapters or bypass fittings.
The heat pump has a three-year supplier warranty. The compressor is covered for seven years, with seven-year cover against corrosion for the titanium coil. Cover applies to manufacturing defects and becomes parts-only after year three. The longer component periods do not extend the whole-unit warranty to seven years.
Frost damage is excluded. Follow the manual when draining and winterising equipment that is taken out of service, and retain your purchase and installation records. Contact us for help with a suspected manufacturing fault.
Other heat pumps to compare
Compare nearby models and alternative ranges before choosing your heater.
- Remora F6 6.12kW On/Off Heat Pump with Wi-Fi for Koi Ponds and Pools — Lower rated output in this range: 6.12 kW at A24/W26; single-phase supply.
- Remora F10 10.49kW On/Off Heat Pump with Wi-Fi for Koi Ponds and Pools — Higher rated output in this range: 10.49 kW at A24/W26; single-phase supply.
- Thermotec Apex 8kW Inverter Pond Heat Pump — An alternative range to compare: 8.02 kW at A27/W26; single-phase supply. This alternative offers inverter control, vertical air discharge. Check operating temperatures, water flow and installation requirements against your intended use.
Rated heating output is measured at the stated air and water temperatures. In these figures, A means air temperature and W means water temperature, both in degrees Celsius. Heating output is not electrical consumption or a guarantee of winter performance. For a koi pond, compare the minimum water setpoint and cold-weather output as well as the headline kW rating.
Electrical supply and UK socket connection
Maximum current: 9.58A.
Supplied with a 2.8m cable and UK plug, according to the UK supplier. It can connect to a suitable 13A UK socket with the protection and outdoor installation specified in the instructions. For the optional hardwired installation, the supplier lists a 16A C-type circuit breaker. This is not the fuse rating for the supplied plug.
See our Remora Heat Pumps range guide and model comparison, or compare all air source heat pumps.
Availability and delivery
Most of our heat pumps are kept in stock. Some models may be dispatched directly from our supplier, and availability can change. Please allow 1–2 weeks for delivery where additional lead time is needed. We will keep you informed of your order’s progress and expected delivery date. If you need your heat pump by a particular date, please contact us before ordering so we can confirm the current lead time.



Reviews