Black Knight Filter Brush 10 x 8 Inches
| Brand | |
|---|---|
| Length | 10 inches |
| Diameter | 8 inches |
| Filament material | Hydrotek polypropylene |
| Core | Stainless steel wire |
| Quantity | 1 brush |
This Black Knight filter brush measures 10 inches long by 8 inches in diameter. Its polypropylene filaments are carried on stainless steel wire, providing a reusable surface that traps suspended waste as water passes through a suitably arranged brush chamber.
£4.99 (inc VAT)
Out of stock
Out of stock
Black Knight Filter Brush 10 x 8 Inches
Reusable 10-inch brushes for a planned rectangular filter layout
This Black Knight filter brush measures 10 inches long by 8 inches in diameter. Its polypropylene filaments are carried on stainless steel wire, providing a reusable surface that traps suspended waste as water passes through a suitably arranged brush chamber.
Product details
| Brand | Black Knight |
|---|---|
| Length | 10 inches |
| Diameter | 8 inches |
| Filament material | Hydrotek polypropylene |
| Core | Stainless steel wire |
| Quantity | 1 brush |
| Supplier code | FM245 |
A short brush with a broad diameter
The 10 x 8-inch version is useful when a filter layout needs an 8-inch brush diameter but has less room for brush length. Its nominal dimensions convert to approximately 254mm long by 203mm in diameter. These are conversions of the listed imperial size, rather than an extra precision or a guarantee of clearance inside a particular filter.
Length and diameter solve different fit questions. The 10-inch dimension helps you assess the usable depth; the 8-inch dimension determines how the brushes will occupy the chamber when viewed from above. Check both before ordering. Allow access for removal, and account for support rails, pipe entries and the shape of the base when measuring.
Which chamber shape suits this diameter?
Black Knight’s guidance favours 8-inch brushes in larger rectangular chambers. A shorter length does not change how an 8-inch circle packs into the chamber’s footprint. For a round chamber, the manufacturer recommends looking at 4- or 6-inch diameters instead, because the wider brushes can leave gaps around the curved sides.
If you need greater working length while retaining this diameter, compare the 16 x 8-inch Black Knight filter brush. Measure the space rather than selecting by pond volume alone. Neither brush has an individual pond-capacity rating that can replace a properly designed filtration system.
Construction and filtration role
The Black Knight range is made in Kent by Speedy Brush. Hydrotek polypropylene filaments are held between two twisted stainless steel wires to form the cylindrical brush. This provides a reusable mechanical medium with exposed surfaces on which filter bacteria can establish. It is a pond filter brush, distinct from the softer spawning brushes in the Black Knight range.
As water passes through the arranged brushes, suspended waste is intercepted. The brush holds that waste until maintenance removes it. This is why a chamber can appear to be collecting dirt effectively while still needing attention: the solids remain in the water system until they are drained or washed out.
Work out quantity from the layout
The manufacturer specifies overlapping rows for this diameter. Use the Black Knight spacing guide for the arrangement.
That example addresses chamber footprint and brush diameter; you still need to check whether this 10-inch length suits the working depth. It is not a ready-made specification for a pond of any particular size. Sketch your internal dimensions and mark the inlet, outlet and supports before deciding the quantity. The price on this page is for one brush.
Choose mechanical pre-filtration or a combined chamber
Black Knight describes single-interlocked brushes as an accessible pre-filter arrangement before biological media. Double-interlocked layouts provide a denser path through the brushes, with designs for vertical flow and horizontal combinations. These alternatives have different maintenance access and flow arrangements, so retain the intended layout when replacing existing media.
The manufacturer’s horizontal-combination design uses a calm settlement area ahead of the brushes, while its guidance for linked vertical-flow chambers recommends preceding them with horizontal-flow settlement. These are design examples, not instructions to rearrange every existing filter. Review the Black Knight chamber layouts alongside your own filter’s design.
Reduce turbulence at the inlet
Water should enter the brush chamber gently rather than as a strong jet, according to Black Knight. Fast local flow can disturb settled debris or wash material from the filaments. When investigating poor particle collection, check the inlet and any gaps through the brush layout as well as whether the brushes themselves are dirty.
Remove collected waste without neglecting the chamber
Black Knight recommends cleaning established brushes with pond water. For a chamber with a bottom drain, its procedure is to stop inflow, empty the chamber, flush the brushes and chamber with pond water, then close the drain and resume filtration. Follow the filter’s own safe isolation and restart instructions when applying that approach.
Have the cleaning water and a suitable place for removed brushes ready before opening the filter. Clear the waste from the base as well as from the filaments, and check that the brushes return to their intended positions. Leaving a missing row or a large gap after cleaning changes the route available to the water.
Check water quality as well as appearance
A clear-looking pond is not proof that ammonia and nitrite are controlled. Regular tests remain useful after cleaning or changing media. The Colombo Pond Test Lab Professional includes these separate measurements. Record them alongside maintenance dates to build a more useful picture of filter performance than appearance alone.