Poolex Silverline Top 150T 15kW Three Phase Heat Pump for Pools and Koi Ponds
| Brand | |
|---|---|
| Rated heat output | 10–15 kW |
| Heating type | Air source heat pump |
| Wi-Fi control | Built in |
| Heating control | Inverter |
| Power supply | Three phase |
| Air discharge | Vertical |
| Electrical input | Reference electrical input at A26/W26, 80% relative humidity: 0.38–2.56 kW, Reference electrical input at A15/W26, 70% relative humidity: 0.46–2.42 kW, Reference maximum electrical input: 3.50 kW |
| Pond Capacity | 15,000–20,000 litres |
Silverline Top 150T three phase inverter heat pump with Wi-Fi, vertical air discharge and 5.3m³/hour water flow. Minimum heating setting 15°C; choose another control range for 12°C pond holding.
£2,187.00 (inc VAT)
Poolex Silverline Top 150T 15kW Three phase Heat Pump for Pools and Koi Ponds
At a glance
- Model heat-output rating: 15 kW
- Power supply: Three phase
- Compressor control: Inverter
- Air discharge: Vertical
The model rating is heat delivered to the water, not electricity consumption. Compare the test conditions and cooler-weather figures in the technical specifications below.
Temperature setting: heating starts at 15°C. The standard heating controls cannot maintain a 12°C winter pond target.
Vertical air discharge and Wi-Fi control, with a 15°C minimum heating setting
The 150T is the three-phase version in this part of the range. It is a distinct electrical choice from the single-phase 150 and requires a suitable three-phase installation. The Silverline Top combines inverter control with an upward discharge arrangement, providing an alternative layout to a front-discharge heater. It still needs clear outdoor airflow and access for installation and maintenance.
The published heating setpoint range is 15–40°C. For koi ponds, this makes the target temperature an essential part of the selection. This controller range does not provide a 12°C winter holding setting. If that is your aim, compare the other air source heat pumps with a suitable lower heating setpoint before ordering.
Silverline Top 150T technical specifications
| Manufacturer model code | PC-TOP150T |
|---|---|
| 2025–2026 catalogue heating rating | 15 kW |
| Catalogue COP, air 26°C / water 26°C | 5.86–11.05 |
| Electrical version | Three phase |
| Published water flow | 5.3 m³/hour |
| Heating setpoint range | 15–40°C |
| Compressor control | Inverter |
| Air discharge | Vertical |
| Wi-Fi | Built in, 2.4GHz |
| Refrigerant | R32 |
| Heat exchanger | Titanium |
Choosing for a swimming pool or warmer koi pond
Start with the water temperature you want to maintain and the months of operation. A swimming pool used mainly in summer and a covered koi pond heated through winter have different demands. A model that is suitable for one installation cannot be selected for the other simply because the number of litres is similar.
For pond use, explain the volume, surface dimensions, construction, insulation, cover, location and exposed filtration. If your chosen target is 15°C or above, the control range is only the first check; the available heating capacity must also cover the installation’s losses in the intended weather. A higher target can require significantly more heat than modest winter holding, so have the complete duty assessed.
For a pool, include its surface area, cover use, wind exposure and intended swimming season. Published pool-volume guidance is tied to assumptions about operating conditions. Compare output at matching air and water temperatures rather than treating the model number or a warm-weather maximum as guaranteed winter performance.
Understanding inverter heating
Inverter control adjusts compressor operation within the unit’s working range as demand changes. It can increase output when the water needs more heat and reduce operation as the target is approached. This is different from a fixed-speed compressor cycling at one operating speed. The benefit in a particular installation still depends on correct sizing, circulation and siting.
Heating output and electrical input are different measurements. Efficiency figures also depend on the test conditions. Use comparable figures when assessing two heaters, and do not apply a maximum advertised COP to every hour of the season. Covering and insulating the installation reduces the heat that the equipment needs to replace.
Planning the 5.3m³/hour water circuit
The heater needs the specified water circulation while operating. Check what the pump can supply through the actual filter, hoses or pipework and fittings. The maximum advertised pump flow is measured under different conditions from a complete installed circuit, so it should not be taken as the flow reaching the heat exchanger.
Have an appropriate bypass and isolation arrangement included where the installation requires it. This allows the heater circuit to be balanced and makes future servicing more practical. Confirm the exact unions supplied with the unit before ordering connection parts, support the pipework properly and leave room to disconnect and drain the heater.
Vertical discharge and outdoor space
The upward fan discharge can help with the layout of a restricted plant area, but it does not make the heater suitable for an enclosed box. Keep the required space above the fan and around the air inlet clear. Follow the manufacturer’s clearances and avoid positioning the unit where a low roof or obstruction sends cooled air back towards the inlet.
Choose a stable base, provide a suitable route for condensate and retain access to the controller, water connections and service panels. Consider delivery and moving the unit into position before building surrounding structures. Planting, stored equipment and covers should not be allowed to block the operating air path.
Electrical supply and model selection
This listing is for the three phase 150T. Have a qualified installer check supply capacity, circuit protection, cable design and isolation against the exact unit’s instructions. A similarly named heater with another electrical configuration is not an interchangeable substitute.
Resolve electrical work before ordering, particularly when replacing a smaller heater or introducing three-phase equipment. Remote control does not remove the need for safe local isolation. The installation must also maintain the necessary water circulation whenever the heater’s operating sequence requires it.
Wi-Fi, daily checks and winter care
Built-in 2.4GHz Wi-Fi allows remote control through the Poolex app. Check signal coverage where the heater will be installed, follow the pairing instructions and keep access to the local controls. App readings are useful for routine monitoring but should be accompanied by physical checks of circulation, drainage and equipment condition.
Make changes to a koi pond’s temperature gradually and monitor with a suitable thermometer. Follow the manual’s maintenance and fault guidance rather than repeatedly resetting a unit that has stopped. If the heater will be taken out of use in freezing weather, drain and winterise it as instructed; switching off electricity alone does not empty the water circuit.
Explore the wider pond heating range and our pond heating guide for help planning the complete system. Provide the intended target and season when asking for a model recommendation.
Installation and operating instructions
Read the Poolex Silverline Top installation manual when planning the position, water circuit, controls and electrical connection. Match the model identification on your supplied unit to its accompanying instructions, and retain those instructions for maintenance and winterisation.
Included fittings and warranty
The UK distributor lists 50mm / 1½-inch water fittings, a condensate drain hose, rubber feet, winter cover, maintenance kit and user manual with the Silverline Top range. Check the connection layout on your installation before ordering any additional pipework or bypass components.
The distributor lists a three-year heat-pump warranty, five years for the compressor and ten years for the titanium coil against corrosion. Cover applies to manufacturing defects, with parts-only cover after year three. Frost damage is excluded: follow the draining and winterisation instructions whenever the unit is unused in freezing weather. Keep the purchase details and the instructions supplied with your particular model.
Compare other Poolex Silverline Top models
Compare heating output at matching air and water temperatures, and check the required water flow and electrical supply. For pond use, confirm that the controller settings suit your intended water temperature before choosing the heating capacity.
- Poolex Silverline Top 120 Single phase Heat Pump for Pools and Koi Ponds
- Poolex Silverline Top 150 Single phase Heat Pump for Pools and Koi Ponds
- Poolex Silverline Top 200 Single phase Heat Pump for Pools and Koi Ponds
- Poolex Silverline Top 200T Three phase Heat Pump for Pools and Koi Ponds
- Poolex Silverline Top 60 Single phase Heat Pump for Pools and Koi Ponds
- Poolex Silverline Top 90 Single phase Heat Pump for Pools and Koi Ponds
Other heat pumps to compare
Compare nearby models and alternative ranges before choosing your heater.
- Poolex Silverline Top 200T 19.93kW Three phase Heat Pump for Pools and Koi Ponds — Higher rated output in this range: 19.93 kW published rating; see its specification table for test conditions; three-phase supply.
- Poolex Jetline Premium Fi 155 21.43kW Three-Phase Heat Pump with Wi-Fi — An alternative range to compare: 21.43 kW at A26/W26; three-phase supply. This alternative offers horizontal air discharge. Check operating temperatures, water flow and installation requirements against your intended use.
- Poolex Jetline Premium Fi 210 28.42kW Three-Phase Heat Pump with Wi-Fi — An alternative range to compare: 28.42 kW at A26/W26; three-phase supply. This alternative offers horizontal air discharge. Check operating temperatures, water flow and installation requirements against your intended use.
Rated heating output is measured at the stated air and water temperatures. In these figures, A means air temperature and W means water temperature, both in degrees Celsius. Heating output is not electrical consumption or a guarantee of winter performance. For a koi pond, compare the minimum water setpoint and cold-weather output as well as the headline kW rating.
Electrical consumption: published catalogue reference
The earlier Silverline Top 150T performance sheet lists the figures below for its 15.00kW catalogue profile. The sheet marks its values as non-contractual and in testing. Treat them as provisional comparison figures, not a verified electrical rating for the unit supplied.
| Reference electrical input at A26/W26, 80% relative humidity | 0.38–2.56 kW |
|---|---|
| Reference electrical input at A15/W26, 70% relative humidity | 0.46–2.42 kW |
| Reference maximum electrical input | 3.50 kW |
A26/W26 means 26°C air and 26°C water. These are electrical consumption figures, not heat output. The inverter varies its demand, so maximum input is not continuous consumption. Later Poolex revisions differ: confirm the supplied unit’s nameplate and manual before using these figures for a running-cost commitment or electrical design. They do not establish a fuse size, breaker rating or suitability for a UK socket.
See our Poolex Silverline Top Heat Pumps range guide and model comparison, or compare all air source heat pumps.
Availability and delivery
Most of our heat pumps are kept in stock. Some models may be dispatched directly from our supplier, and availability can change. Please allow 1–2 weeks for delivery where additional lead time is needed. We will keep you informed of your order’s progress and expected delivery date. If you need your heat pump by a particular date, please contact us before ordering so we can confirm the current lead time.



Reviews