Filtreau Excellent Drum Filter Replacement Control Box
| Brand | |
|---|---|
| Manufacturer reference | CBT0001EX |
Replacement control box for the Filtreau Excellent drum-filter system. Manufacturer reference: CBT0001EX. Check your existing controller and filter connections when choosing the replacement.
Contact us for a current price and help matching your controller.
Filtreau Excellent Drum Filter Replacement Control Box
Replacement controller for the automatic cleaning system on an Excellent drum filter
The Filtreau Excellent replacement control box is the electrical controller for the Excellent drum-filter system. It coordinates the cleaning cycle and provides the connections used by the filter’s pumps, drum motor, UV-C equipment and safety sensors. Filtreau identifies its complete Excellent replacement control box as CBT0001EX.
Choose this spare when the control box has been identified as the faulty component on your existing filter. Before ordering, compare the filter model, controller label and connector arrangement with the replacement required. If you need help, send us photographs of those details so we can check the correct configuration with you.
Automatic cleaning and manual rinsing
Filtreau’s Excellent Line manual describes automatic cleaning triggered by the float switch, together with a manual rinse button. During a cleaning cycle, the drum motor and rinse pump work together to wash accumulated material from the screen and carry it towards the waste outlet. The manual lists a ten-second drum-rinsing time for the illustrated control system.
The manual rinse function is useful when checking the filter after maintenance or commissioning. It allows the cleaning sequence to be observed without waiting for the next automatic cycle. Follow the instructions supplied for your filter and keep its protective cover in place during operation. A new controller still depends on the connected float, pump, motor and pipework working correctly.
Filtreau specifies protection against prolonged flushing, with shutdown after five minutes and a manual reset. Investigate the cause before restarting the system.
Understanding the controller connections
The manufacturer’s control-box diagram separates the connections by their purpose. Use the labels on your own unit when identifying cables; a similar-looking socket is not a reason to interchange connected equipment.
| Connection or control | Purpose in the Excellent system |
|---|---|
| Manual rinse button | Starts a cleaning cycle for checking or rinsing the drum |
| Power button | Switches the control system on or off |
| Rinse-pump and motor connections | Operate the washing pump and drum drive |
| Pond-pump and UV-C connections | Connect the designated filtration equipment |
| Float connection | Receives the signal used for automatic cleaning |
| Cover-protection connection | Works with the magnetic lid-safety system |
The Excellent manual also identifies two safety fuses. Have a competent technician investigate a failed fuse or electrical fault and select the correct replacement specification. Repeatedly replacing a fuse without finding the cause can leave the original fault unresolved.
Check the whole cleaning circuit before replacing the box
A drum that does not rinse correctly can have a fault elsewhere in its cleaning circuit. Useful observations include whether the pond pump runs, whether a manual rinse starts, whether the drum rotates and whether water reaches the spray bar. Record what happens before switching equipment off for inspection. These details help distinguish an electrical-control problem from a blocked water supply, obstructed screen or mechanical problem.
Check routine maintenance items in accordance with the filter manual, including the screen and waste channel. A controller replacement will not remove accumulated debris or repair a worn drum component. Our pond filter spares cover other replacement components, while the drum filter range helps you identify complete filtration systems.
Lid protection and installation
Filtreau describes a magnetic protection system that switches the control box off when the filter cover is removed. Retain that protection when replacing the controller. It helps prevent operation while the drum and UV-C equipment are exposed; do not bypass it to keep a filter running with the lid open.
Disconnect the electrical supply before changing connections or carrying out maintenance. The Excellent manual requires an earthed supply with residual-current protection rated at no more than 30mA. Protect the plug and socket from moisture and arrange a drip loop so water cannot run along a cable into the electrical connection. Have installation and electrical fault-finding carried out by a suitably qualified person.
Commissioning the replacement
After installation, follow the filter’s commissioning procedure. Confirm that equipment is connected to its designated sockets, the cover protection is working and the filter has the correct operating water level. Observe a complete cleaning cycle and check the water connections for leaks before returning the system to normal use.
Continue monitoring pond water while filtration is being repaired or restarted. The Colombo Pond Test Lab Professional provides a practical way to check water parameters alongside the mechanical checks. Keep your controller reference and a record of the repair with the filter instructions for future servicing.
For the manufacturer’s diagrams and system instructions, see the Filtreau Excellent Line manual. Match the illustrated arrangement to your installed filter before carrying out any work.