Elecro Cygnet EVO2 Aquatic Heater 1kW (Analogue)

SKU: HE8020
GTIN: 5056101804059
Brand

Heating Output

1kW

Control Type

analogue thermostat control

Best Use

koi ponds, quarantine systems and pond systems where direct electric in-line heating is required

Installation Type

External in-line installation

Connection Size

1½ inch / 50mm

Heating type

In-line electric heater

Elecro 1 kW titanium in-line pond heater with analogue control. 1.2°C thermostat differential and a required flow of 1,000–17,000 l/h; size around actual heat loss.

£489.99 (inc VAT)

Elecro Cygnet EVO2 1 kW Analogue Pond Heater

Direct electric heating with analogue temperature control

The 1 kW version is the lowest output in this Cygnet EVO2 range. It suits a heating plan with a relatively modest heat requirement, provided the element can replace the heat the system loses.

The Cygnet version uses a grade 1 titanium heating element and titanium flow tube. This analogue model controls the temperature with a thermostat dial.

Specification Details
Nominal heater output 1 kW
Electrical configuration 220–240 V single phase; confirm the supplied unit and installation requirements
Control Analogue thermostat, 0–45°C control range
Thermostat differential 1.2°C
Required flow through the heater 1,000–17,000 litres/hour
Heating element and flow tube Grade 1 titanium
Connections 1½-inch BSP female; supplied 1½-inch / 50 mm stepped unions and 1¼-inch / 1½-inch hose tails
Maximum working pressure 4 bar
Ingress protection IP44; install within the dry, weatherproof environment required by the manual

What the analogue control changes

Elecro specifies a 1.2°C thermostat differential for the analogue model. The matching digital version uses a 0.5°C differential and gives a numerical control display.

The differential describes the control switching band. It is not a promise that every point in the pond will stay within that distance of the set temperature, and it is not a stated ±temperature-measurement accuracy. Both control versions at 1 kW have the same nominal heating output.

The upper thermostat setting is a product capability, not a recommended pond temperature. Choose the target for the fish and the way the system is managed, allowing for gradual changes.

Flow, mounting and installation

Plan around the actual flow through the heater, after the pipework and filter have reduced the pump’s headline output. The manufacturer gives a minimum of 1,000 l/h and a maximum of 17,000 l/h. Its flow switch and over-temperature protection are safeguards; the installation must still keep the heater full of water and free of trapped air.

Use the mounting arrangement in the unit instructions, within a dry, permanent weatherproof area with access for service. The heater is positioned after the filter and before dosing equipment. Connecting pipework needs at least a 32 mm internal bore and the specified return-pipe safety loop to help it remain full and purge air.

A qualified electrician must install the supply and the manufacturer’s required protective circuit. The exact heater version and its supplied manual determine those requirements. Check the manufacturer’s permitted water-quality limits as part of the installation and maintenance plan.

Sizing and electricity use

Size the heater around water volume, exposed surface area, insulation, cover use, weather and the temperature to be maintained. A thermostat cannot compensate for a heater that is too small to replace the heat being lost.

At continuous full element output, this 1 kW version uses about 1 kWh in an hour. Multiply that by your electricity unit rate for an estimate of that hour’s heater cost. Actual running time depends on demand; pump consumption is additional.

Our pond heating guide explains those choices. You can also compare air-source pond heat pumps where the heating requirement and operating conditions suit that approach.

Related equipment and routine care

Compare the same-output digital Cygnet EVO2 if you prefer the other control format. Browse the Elecro in-line pond heaters for other outputs, and plan suitable pipework and fittings around the selected unit.

Check the water circulation, connections and any deposits during maintenance. Follow the unit instructions for isolation, cleaning, frost protection and restarting; do not assume the titanium construction removes the need for those checks.

Elecro Cygnet EVO2 Aquatic Heater 1kW (Analogue) Reviews

Reviews

There are no reviews yet.

Be the first to review “Elecro Cygnet EVO2 Aquatic Heater 1kW (Analogue)”