Charles Austen ETi150A Air Pump with Alarm
| Dimensions | 273 × 200 × 232 mm |
|---|---|
| Brand | |
| Air Flow | 150 L/min |
| Air Pressure | 0.15 bar |
| Power | 90 W |
| Model | ETi150A |
| Version | ETi A with alarm |
| Flow measurement | Rated airflow at the stated duty pressure |
| Published sound level | 42 dB(A) |
| Connection | 18 mm pump outlet |
| Low pressure alarm | Integrated LED warning and audible buzzer |
| External alarm | Not fitted |
| Service interval | 12 months |
The Charles Austen ETi150A is an oil free linear diaphragm air pump rated at 150 litres per minute at 0.15 bar, with published power of 90 W. Includes an integrated LED low pressure alarm and audible buzzer. Suitable for correctly sized pond, biological filter and compatible wastewater aeration duties.
Manufacturer product weight 8.9 kg; dimensions 273 × 200 × 232 mm, depth × width × height. Compare the performance curve at your required pressure and check the supplied connector details before selecting airline. Fulfilled by Enviro.
£272.99 (inc VAT)
Charles Austen ETi150A Air Pump
The Charles Austen ETi150A is an ETi series linear diaphragm air pump with an integrated LED low pressure alarm and audible buzzer. It is an option for pond and koi aeration, biological filtration and compatible sewage treatment systems where an additional low pressure warning is useful.
The integrated LED warning and audible buzzer help draw attention to low pressure output. If you need to connect a separate warning device, compare the corresponding AO version and check the device and wiring requirements. Select the pump for the airflow and operating pressure your complete system requires.
Key features
- Charles Austen ETi series linear diaphragm air pump
- Integrated LED warning and audible buzzer for low pressure output
- Compare the AO version if an external warning output is needed
- Suitable for correctly sized pond, biological filter and wastewater aeration installations
- Service parts must be matched to the exact model
Technical overview
| Model | ETi150A |
|---|---|
| Manufacturer / brand | Charles Austen |
| Pump type | Oil free linear diaphragm air pump |
| Rated airflow at 0.15 bar | 150 litres per minute |
| Published power | 90 W |
| Published sound level | 42 dB(A) |
| Product weight | 8.9 kg |
| Dimensions, depth × width × height | 273 × 200 × 232 mm |
| Pump outlet diameter | 18 mm |
| Alarm | Integrated LED warning and audible buzzer for low pressure output |
| Energy at continuous 24 hour operation | 2.16 kWh per day |
| Energy at continuous operation for 365 days | 788.40 kWh per year |
Sound figures are manufacturer quoted values; installed noise depends on the location and operating conditions.
What is supplied
- Charles Austen ETi150A air pump with an integrated LED low pressure alarm and audible buzzer.
The manufacturer’s datasheet does not confirm a supplied connector and elbow accessory pack for the ETi150 or ETi200 sizes. Confirm the required connecting parts when ordering rather than assuming the smaller models’ accessories are included.
Choosing standard ETi, A or AO
The corresponding standard ETi, A and AO models share the airflow, power, sound, weight and dimensions stated in the manufacturer’s datasheet. Choose the version for its warning and monitoring requirements as well as its aeration duty.
- Standard ETi: the standard pump version.
- ETi A: adds an integrated low pressure alarm with an LED warning and audible buzzer.
- ETi AO: adds the integrated alarm and an output cable for connection to a compatible external beacon or monitoring arrangement.
Confirm the external device and wiring requirements before installation. A low pressure alarm does not identify every possible fault: a blocked diffuser can increase pressure instead.
Using the performance curves
The rated airflow is stated at 0.15 bar. Airflow changes as the system pressure changes, so use the correct model curve to compare the air available at your installation’s working pressure. Free air delivery near zero pressure is different from the rated duty point.
Allow for water depth, diffuser resistance, airline bore and length, fittings and normal fouling. The point where a plotted curve approaches zero airflow is not a recommended working pressure or a guaranteed diffuser depth. Compare ETi, ET and ETD models at the same required duty rather than choosing by the model number alone.
The separate power curve shows that electrical consumption also varies with pressure. Any daily or annual energy figures on this page are calculations from the published rated wattage for continuous operation, not metered results for every installation.
How the alarm helps
A warning can make a pressure or airflow fault easier to notice, particularly where a treatment plant pump is out of sight. Check the pump, airline and connected equipment promptly if the alarm activates. A low pressure warning is not a guarantee that every fault will be detected: for example, a blocked diffuser may increase pressure instead.
Should I choose an ETi, ET or ETD air pump?
Start with the total airflow your installation needs at its actual working pressure. Water depth, diffuser resistance, airline bore, hose length and restrictions all affect the duty. The ETi model number corresponds to the manufacturer’s nominal airflow at 0.15 bar; actual delivery changes with operating pressure. Compare the Charles Austen ETi150 air pump with the alarm version here, and check each model’s individual performance information before ordering.
The Charles Austen ET range offers other sizes and duties; ETD models are another option for some larger systems. Matching numbers do not on their own prove equal airflow or pressure. Browse the ETi range and contact us if you would like help matching a pump to your installation.
Related Charles Austen options
Compare the matching Charles Austen ETi150 Air Pump and Charles Austen ETi150AO Air Pump with Alarm and External Output.
- Charles Austen ETi150 air pump: the corresponding ETi pump without the added alarm box.
- Charles Austen ETi150AO: the corresponding alarm and output cable option.
Installation and commissioning
Position the pump on a stable surface with ventilation, protect it from flooding and follow the installation instructions supplied with the pump. Where water could siphon back through an airline, use suitable non return protection. Size pipework, manifolds and diffusers for the full airflow and pressure of the installation.
Check the alarm is positioned where a warning can be noticed. For an external device, a suitably qualified installer should check the output and connection requirements against the manufacturer’s instructions.
Maintenance and servicing
Charles Austen recommends servicing every 12 months. Inspect the air intake, airline, connectors and diffusers between services, and keep the pump ventilated and protected from flooding or water siphoning back through the airline. Leaks, kinks and fouled diffusers can reduce useful airflow without an internal pump failure.
Match diaphragms, valves, filters and service parts to the exact ETi model. Do not assume ET and ETi service components are interchangeable because they share a number. Follow the current manufacturer’s service and warranty terms and keep a service record where continuous aeration is critical.
Service parts and compatibility information: Charles Austen air pump service parts.
Recommended diffusers, manifolds and airline
Match diffusers to the pump’s airflow at the working depth. Choose between standard sinking airline and heavy duty sinking airline according to the run and duty, checking the hose bore and fittings.
To split airflow, consider a 2 way air manifold or 4 way air manifold. For larger runs, consider the 10 mm or 14 mm outlet options where suitable. Match the manifold inlet to the pump connection as well as the outlets to the airline, and check the complete system does not create excessive restriction.
Help choosing the right pump
If you are replacing an existing treatment plant pump or sizing a pond system, have the existing pump model, number and depth of diffusers, airline size and run length to hand. We can help you compare the options.
Dispatch and image: Dispatched directly by Enviro. The photograph shows an ETi100AO and is representative of the ETi A and AO range; label details may vary.
Northern Ireland delivery: Free delivery does not apply to Northern Ireland. Delivery costs £35 per order, including VAT.






Reviews