Charles Austen ETI60 Air Pump

SKU: ETI60
Dimensions 208 × 151 × 188 mm
Brand

Air Flow

60 L/min

Air Pressure

0.15 bar

Power

32 W

Model

ETi60

Version

Standard ETi

Flow measurement

Rated airflow at the stated duty pressure

Published sound level

36 dB(A)

Connection

16.2 mm connector

Low pressure alarm

Not fitted

External alarm

Not fitted

Service interval

12 months

Supplied fittings

Screw in barbed connector; rubber elbow; two clips

The Charles Austen ETi60 is an oil free linear diaphragm air pump rated at 60 litres per minute at 0.15 bar, with published power of 32 W. Suitable for correctly sized pond, biological filter and compatible wastewater aeration duties.

Manufacturer product weight 4.9 kg; dimensions 208 × 151 × 188 mm, depth × width × height. Compare the performance curve at your required pressure and check the supplied connector details before selecting airline. Fulfilled by Enviro.

£101.99 (inc VAT)

Charles Austen ETi60 Air Pump

The Charles Austen ETI60 Air Pump is a compact oil-free linear diaphragm air pump for pond aeration, biological filters, hydroponic nutrient reservoirs and small wastewater-treatment systems. The manufacturer rates this model at 60 L/min at 0.15 bar, with published power of 32 W. Check the model performance curve when sizing the pump for your working pressure.

This model belongs to the Charles Austen ETi range. The model number corresponds to the manufacturer’s nominal airflow at 0.15 bar, not guaranteed delivery at every pressure. Compare the performance curves and connection details for the exact models before choosing a replacement.

In ponds and koi systems, reliable aeration supports dissolved oxygen, water movement and the aerobic bacteria inside biological filters. In hydroponic reservoirs it helps circulate oxygen through the nutrient solution. In treatment systems, airflow supports the aerobic process used to break down waste. Final sizing must allow for diffuser depth, airline length, manifold losses and normal fouling.

Key features

  • Oil-free linear diaphragm air delivery for aquatic and treatment applications.
  • Manufacturer-rated airflow 60 L/min at 0.15 bar.
  • Rated electrical consumption of 32 W.
  • Manufactured by Charles Austen.
  • Suitable for continuous aeration duties when correctly installed, ventilated and serviced.
  • Model-specific comparison with the standard Charles Austen ET range.

Technical overview

Model ETi60
Manufacturer / brand Charles Austen
Pump type Oil free linear diaphragm air pump
Rated airflow at 0.15 bar 60 litres per minute
Published power 32 W
Published sound level 36 dB(A)
Product weight 4.9 kg
Dimensions, depth × width × height 208 × 151 × 188 mm
Manufacturer confirmed connector 16.2 mm
Energy at continuous 24 hour operation 0.77 kWh per day
Energy at continuous operation for 365 days 280.32 kWh per year

Sound figures are manufacturer quoted values; installed noise depends on the location and operating conditions.

The manufacturer confirms the ETi60 connector as 16.2 mm. This figure is not a confirmed hose internal diameter or thread specification; match the actual connector arrangement before fitting airline.

What is supplied

  • Charles Austen ETi60 air pump.
  • Screw in barbed connector.
  • Rubber elbow connector and two clips.

The 18 mm and 20 mm brass barbed connectors shown as options for the ETi60 to ETi120 sizes are optional items, rather than the standard supplied connector. Select any optional connector separately and check the complete connection arrangement.

Choosing standard ETi, A or AO

The corresponding standard ETi, A and AO models share the airflow, power, sound, weight and dimensions stated in the manufacturer’s datasheet. Choose the version for its warning and monitoring requirements as well as its aeration duty.

  • Standard ETi: the standard pump version.
  • ETi A: adds an integrated low pressure alarm with an LED warning and audible buzzer.
  • ETi AO: adds the integrated alarm and an output cable for connection to a compatible external beacon or monitoring arrangement.

Confirm the external device and wiring requirements before installation. A low pressure alarm does not identify every possible fault: a blocked diffuser can increase pressure instead.

Compare Charles Austen ETI and standard ET air pumps

ET and ETi are different Charles Austen ranges. Compare the complete performance curve at your operating pressure, the outlet, dimensions, electrical supply and service requirements before replacing one model with another. Matching model numbers do not prove the pumps interchangeable.

Explore the related models and ranges: Charles Austen ET60 Air Pump; Charles Austen ET30 Air Pump; Charles Austen ETI Series; Charles Austen ET Series.

Compare ETI models

Compare the matching Charles Austen ETi60A Air Pump with Alarm and Charles Austen ETi60AO Air Pump with Alarm and External Output.

The manufacturer rates these models at 0.15 bar. Compare the complete performance curves at your installation’s working pressure as well as the published power.

Model Rated airflow Duty pressure Published power
Charles Austen ETI80 Air Pump 80 L/min 0.15 bar 45 W
Charles Austen ETI100 Air Pump 100 L/min 0.15 bar 65 W
Charles Austen ETI120 Air Pump 120 L/min 0.15 bar 75 W
Charles Austen ETI150 Air Pump 150 L/min 0.15 bar 90 W
Charles Austen ETI200 Air Pump 200 L/min 0.15 bar 100 W

How to size the ETI60

Add together the airflow required by the diffusers and equipment connected to the pump. Allow for water depth, pipe length, fittings and diffuser resistance when establishing the working pressure. Check the exact model performance curve at that pressure and leave appropriate capacity for the installation.

Use suitable airline and avoid excessive restriction. Follow the manufacturer instructions and seek advice if replacing a pump on a treatment system.

Choosing between the ET, ETD and ETi ranges

Choose an air pump for the airflow your installation needs at its working pressure. Water depth, diffuser resistance, pipe length and fittings all affect the required duty in ponds, lakes and sewage treatment systems.

The ET range covers a variety of aeration duties. ETD models offer another option for larger systems; compare the exact models at the pressure your installation requires. The ETi range is a further option: matching model numbers do not necessarily mean matching airflow. Compare the stated duty and power before choosing.

A models add a pressure alarm; AO models add an output connection for a compatible separate warning device. Check the exact model and the external device compatibility. A low pressure alarm may not identify every blockage, because restrictions can increase pressure.

Maintenance and servicing

Charles Austen recommends servicing every 12 months. Inspect the air intake, airline, connectors and diffusers between services, and keep the pump ventilated and protected from flooding or water siphoning back through the airline. Leaks, kinks and fouled diffusers can reduce useful airflow without an internal pump failure.

Match diaphragms, valves, filters and service parts to the exact ETi model. Do not assume ET and ETi service components are interchangeable because they share a number. Follow the current manufacturer’s service and warranty terms and keep a service record where continuous aeration is critical.

Service parts and compatibility information: Charles Austen air-pump service-kit page.

Recommended air diffusers and airline

Choose diffusers by their permitted airflow and resistance at the intended depth. The rated pump output does not establish a fixed number of diffuser discs: the total airflow, operating pressure and distribution layout must be checked together. Size the airline bore and manifold for the complete run and avoid unnecessary restriction.

Use suitably sized sinking airline, balance multiple branches and match the manifold inlet to the pump connection. A manifold outlet size is not automatically the correct pump connector size. For larger runs, compare the available 10 mm and 14 mm manifold outlet options against the actual airline bore and pressure losses.

Accessories to compare for a correctly sized installation:

Using the performance curves

The rated airflow is stated at 0.15 bar. Airflow changes as the system pressure changes, so use the correct model curve to compare the air available at your installation’s working pressure. Free air delivery near zero pressure is different from the rated duty point.

Allow for water depth, diffuser resistance, airline bore and length, fittings and normal fouling. The point where a plotted curve approaches zero airflow is not a recommended working pressure or a guaranteed diffuser depth. Compare ETi, ET and ETD models at the same required duty rather than choosing by the model number alone.

The separate power curve shows that electrical consumption also varies with pressure. Any daily or annual energy figures on this page are calculations from the published rated wattage for continuous operation, not metered results for every installation.

Installation and commissioning

For pond, treatment and multi-outlet work, size the diffuser area and manifold for the whole pump output. Dividing a pump across several balanced branches usually gives a more even air pattern than forcing all output through one small diffuser. Use the largest practical airline bore, keep branches similar in length and provide a safe route for surplus air rather than closing most manifold outlets.

After installation, check every outlet for a stable bubble pattern and listen for a change in pump tone. A branch with weak output may be restricted or longer than the others, while a pump that becomes noticeably louder or hotter can be working against excessive back pressure.

Keep the pump above the maximum water level where practical and protect it from flooding, direct spray and recirculated hot air. If it must sit below water level, use the correct non-return protection and route the airline so water cannot siphon into the pump during a power cut.

Performance checks and fault finding

If airflow falls, test the system methodically: inspect the intake, disconnect the manifold to compare unrestricted output, check the airline for leaks or kinks, and clean or replace fouled diffusers. Only diagnose internal pump wear after external restrictions have been ruled out. For critical aeration, keep a contingency pump or alternative oxygen source available during servicing.

Do not assume ET and ETI service parts are interchangeable because two models share a number. Confirm the exact pump code before buying diaphragms, valves or filters, and keep a record of service dates where continuous aeration protects livestock or treatment performance.

Complete your Charles Austen aeration setup

Northern Ireland delivery: Free delivery does not apply to Northern Ireland. Delivery costs £35 per order, including VAT.

Charles Austen ETI60 Air Pump Reviews

Reviews

There are no reviews yet.

Be the first to review “Charles Austen ETI60 Air Pump”