Aquascape Snorkel Vault and Lid V2 with End Cap for Centipede

SKU: AQS-51007
Brand

Product Type

Application

Works With

Ecosystem Filtration

Professional-grade service vault for Aquascape V2 wetland filtration systems. Part 51007 combines the reinforced Snorkel Vault, low-profile lid and Centipede Module End Cap V2. Pair it with one or more Aquascape Centipede Module V2 sections to create the lower distribution run and maintain cleanout access.

£519.99 (inc VAT)

Aquascape Snorkel Vault and Lid V2 with Centipede End Cap

The Aquascape Snorkel Vault and Lid V2 is the service chamber at the heart of a professional Aquascape wetland filtration system. Aquascape part 51007 combines the tall V2 access vault, its reinforced snap-fit lid and the Centipede Module End Cap V2 in one matched package. It is designed to work with one or more Aquascape Centipede Module V2 sections, which form the horizontal water-distribution channel beneath the wetland filter.

Its job is simple but extremely important. The vault provides a clear route to the lowest part of the wetland filter so the installer or pond owner can inspect the system, lower in a cleanout pump and remove accumulated sediment without dismantling the gravel bed. For a large pond or lake filtration project, that service access can make the difference between straightforward routine maintenance and a major excavation.

How the parts work together: the Snorkel Vault forms the vertical service chamber, the linked Centipede Module V2 sections spread incoming water beneath the filter bed, and the supplied end cap completes the far end of the Centipede run. Use one or more modules according to the planned wetland-filter size.

The service point for an Aquascape wetland filter

In an Aquascape wetland filter, water is distributed through one or more linked Centipede Module V2 sections at the base of the filtration zone before rising through the supporting media, rock and gravel above. Their elongated open-channel design slows the incoming water, helps heavier debris settle and spreads the flow across the filter bed before biological treatment takes place.

The Snorkel Vault V2 connects to the first Centipede Module and remains accessible from the finished surface. Additional modules can be joined in series when the wetland footprint requires a longer distribution run, while the end cap supplied with this package completes the final module. When the filter needs cleaning, the vault lid is removed and a suitable cleanout pump can be lowered into the service chamber so settled material can be pumped away without dismantling the gravel bed.

Aquascape wetland filtration system showing Snorkel Vault and Centipede distribution chamber
The Snorkel Vault provides the service route beside the lower Centipede distribution chamber.

Our practical view: wetland filters are excellent on larger ponds when the distribution chamber, media depth, flow and future cleanout access are planned together. The Snorkel Vault should never be treated as an afterthought because it is the part you will rely on whenever the filter needs inspection or a proper clean.

Why choose the V2 Snorkel Vault

  • Generous service opening: the larger opening gives better access for pumps, hoses and hands-on maintenance.
  • Reinforced rotationally moulded body: designed for the loading and demanding conditions found in buried wetland filtration systems.
  • Secure low-profile lid: the supplied snap-fit lid protects the chamber from loose gravel and debris and can be concealed neatly within the finished landscaping.
  • Designed for working landscapes: Aquascape states that the reinforced lid is made to cope with foot traffic and environmental wear when installed correctly.
  • Matched V2 connection: the supplied Centipede Module End Cap V2 completes the end of the current V2 distribution chamber.
  • Expandable finished height: where the filter bed or surrounding landscaping is deeper, the compatible Aquascape Snorkel Vault Extension V2 raises the service opening while maintaining access.
  • Made in the USA: part of Aquascape’s current V2 wetland filtration platform.

What is supplied

  • Aquascape Snorkel Vault V2
  • Reinforced snap-fit Snorkel Vault Lid V2
  • Centipede Module End Cap V2

This package gives you the two end components around the distribution run: the accessible Snorkel Vault at one end and the matching V2 end cap at the other. Add one or more Aquascape Centipede Module V2 sections between them to suit the footprint and design flow of the wetland filter. The cleanout pump, discharge hose, FilterBlox and remaining filtration media are then selected separately for the installation.

Technical specification

Manufacturer Aquascape
Aquascape part number 51007
System generation Current V2 wetland filtration system
Overall dimensions 19.25 Ă— 16 Ă— 42.5 inches (approximately 48.9 Ă— 40.6 Ă— 108 cm)
Construction Heavy-duty rotationally moulded body with reinforced snap-fit lid
Primary role Inspection and cleanout access for an Aquascape wetland filter
Included connection part Centipede Module End Cap V2
Compatible extension Aquascape Snorkel Vault Extension V2, part 51008
Country of manufacture USA

Planning the installation properly

Set the finished access level before backfilling

The vault should stand vertically and its lid must remain reachable after the rock and gravel are installed. Set the height against the final landscaping level rather than the excavated base. If the wetland bed is deeper, use the correct V2 extension rather than burying the lid or improvising an inaccessible chamber.

Leave a clear route for the cleanout pump

Allow enough room above the vault to lift the lid, lower and retrieve the cleanout pump, and route the discharge hose safely away from the pond. A pump and hose should be chosen around the actual lift, sediment load and disposal route. Keeping these service details in mind during construction makes future cleaning considerably easier.

Plan the Centipede and media layout as one system

The Snorkel Vault is positioned beside the first Centipede Module V2 at the base of the filter. Multiple modules snap together in series, so the distribution run can be extended to match the wetland footprint. The number of modules, FilterBlox arrangement, rock grading and total filtration area should be sized for the pond, intended flow and expected debris load. Browse our Aquascape pondless and wetland filtration range when planning the connected parts.

V2 and original Snorkel Vault components

Aquascape’s V2 wetland components are a newer system generation. They are visually similar to the original Large Snorkel Vault range, but the lid, extension and Centipede connections should be selected by part number and generation rather than appearance.

System Choose it when Related parts
Snorkel Vault V2, 51007 Building or extending the current Aquascape V2 wetland system V2 replacement lid and V2 extension
Original Large Snorkel Vault, 29064 Maintaining an existing original-generation installation Original Large Snorkel Vault and Cap and original extension

Common questions

What does the Snorkel Vault do?

It creates a permanent access chamber down to the lower section of an Aquascape wetland filter. This lets you inspect the system and lower in a pump to remove settled sediment without taking the filtration bed apart.

Does this package include the lid?

Yes. Aquascape part 51007 is supplied with the reinforced V2 snap-fit lid as well as the Centipede Module End Cap V2.

How many Centipede Module V2 sections should I use?

The vault is normally paired with one or more Centipede Module V2 sections. The correct quantity depends on the wetland footprint, planned flow and filter design rather than the vault alone. Multiple sections can be snapped together in series. If you are unsure, send us the pond dimensions and a simple layout sketch before ordering.

Can the lid be hidden with rock and gravel?

Yes. The low-profile lid is designed to blend into the finished landscape. Keep it identifiable and readily removable, and avoid permanently covering it with fixed stonework.

Do I need a Snorkel Vault Extension V2?

An extension is useful where the wetland filter bed or surrounding landscape places the finished surface above the standard 42.5-inch vault height. Set the intended finished level before ordering so the access point can be planned correctly.

Can this be connected to the original Aquascape Centipede system?

It is intended for the current Centipede Module V2 system. Original and V2 parts should not be assumed interchangeable. Check the Aquascape part numbers already installed before selecting a lid, extension or connection component.

Is this the same as a pondless waterfall pump vault?

No. This Snorkel Vault V2 is designed as the inspection and cleanout chamber for an Aquascape wetland filter. Aquascape makes separate pump vaults for pondless waterfall reservoirs.

Can a wetland filter be added to an existing pond?

Yes, many wetland filters can be retrofitted beside an existing lined or earth-bottom pond. The available area, levels, return route and required flow all need to be assessed before excavation begins.

Need help planning the wetland filter?

Send us the pond dimensions, a few clear photographs, the proposed filter position and any Aquascape part numbers already on site. As pond installers as well as equipment suppliers, we can help check the component generation and talk through the practical service access before the system is covered with rock and gravel.

Aquascape Snorkel Vault and Lid V2 with End Cap for Centipede Reviews

Reviews

There are no reviews yet.

Be the first to review “Aquascape Snorkel Vault and Lid V2 with End Cap for Centipede”