Find your pond heater

Use pond size as a shortlist, then read the model description for its recommended volume and operating temperatures. A covered pond at 12°C is our winter planning target; supplier volume guides are not a guarantee for every installation. Contact us for help choosing a model for your pond.

Price

Heating type

Rated heat output

Wi-Fi control

Heating control

Power supply

Air discharge

Brand

AquaForte AquaMini Heat Pumps for Seasonal Heating

Compare individual models and installation requirements

Compare the individual 3.5kW, 5.6kW and 7.7kW AquaForte AquaMini models for suitable seasonal water-heating installations. These compact heaters have different output and circulation requirements, which are detailed on each product page.

Browse the complete air source heat pump range to compare brands and controls, or explore other pond heating equipment.

Compare the three AquaMini models

These outputs are measured at the stated air and water temperatures. They are seasonal comparison figures, not winter pond capacities. On a small screen, scroll the table sideways to see every column.

Model Output A27/W27 Output A15/W26 Required flow
AquaForte Heat Pump Aqua Mini 3.5kW 3.5 kW 2.4 kW 1–2 m³/hour
AquaForte Heat Pump Aqua Mini 5.6kW 5.6 kW 3.5 kW 2–2.5 m³/hour
AquaForte Heat Pump Aqua Mini 7.7kW 7.7 kW 4.8 kW 2.5–3.5 m³/hour

Temperature and seasonal suitability

The family manual specifies an outdoor operating range of 10–43°C. This makes operating season an important selection check: do not choose an AquaMini as a substitute for a heat pump intended to continue through freezing winter conditions.

Compare the complete installation

At air 15°C and water 26°C, published heating outputs are 2.4kW, 3.5kW and 4.8kW respectively. Those figures help show why the larger warm-condition model rating should not be used as a constant output. Check the required flow and 32/38mm connections against your planned circuit.

Plan the water circuit using the flow required by the heater after allowing for the installed filter, pipes and fittings. Arrange appropriate isolation and service access, and check the electrical supply with a qualified installer. Outdoor clearance and a clear route for condensate are part of the installation, not optional extras.

Covering and insulating the water reduces heat loss. If a heater is shut down during freezing weather, follow its draining and winterisation instructions; switching off power does not remove trapped water. Our pond heating guide explains the main planning considerations.

Individual model pages

Related heat pump ranges

Air Source Heat Pumps · Jetline Premium · Remora Professional · Remora Inverters · Remora Heat Pumps