Remora Professional 8 8.6kW Inverter Heat Pump with Wi-Fi

SKU: HE605
Brand

Rated heat output

5–10 kW

Heating Output

4.2 to 8.6kW

Best Use

Koi ponds and pools

Heating type

Air source heat pump

Connection Size

1½ inch

Wi-Fi control

Built in

Heating control

Inverter

Power supply

Single phase

Air discharge

Horizontal

Electrical connection

Suitable for standard 13A UK socket

Electrical input

Electrical input at A27/W27: 0.48–1.21 kW, Electrical input at A15/W26: 0.45–1.15 kW

Maximum current

7.5 A

Pond Capacity

5,000–10,000 litres

Remora Professional 8 inverter heat pump with built-in Wi-Fi for koi ponds and swimming pools. Published heating output: 4.2–8.6 kW at air 27°C/water 27°C and 2.4–5.75 kW at air 15°C/water 26°C. Requires 3–5 m³/hour nominal flow. Pond sizing depends on cover, heat loss and target temperature.

£2,445.00 (inc VAT)

Accessories

Remora Professional 8 8.6kW Inverter Heat Pump with Wi-Fi

At a glance

  • Model heat-output rating: 8.6 kW
  • Power supply: Single phase
  • Compressor control: Inverter
  • Air discharge: Horizontal
  • Electrical connection: Suitable for standard 13A UK socket

The model rating is heat delivered to the water, not electricity consumption. Compare the test conditions and cooler-weather figures in the technical specifications below.

Controlled heating and cooling with built-in Wi-Fi

The Remora Professional 8 is the smallest model in the Professional range and gives you a way to manage water temperature using an inverter compressor. It is intended for an installation with a suitable circulating water supply, clear outdoor airflow and a correctly sized heating requirement. Built-in Wi-Fi provides access through the Smart Life app, while local controls remain available at the unit.

For koi keepers, the first decision is what you want the heater to achieve. Holding a covered pond at a moderate temperature during winter is a different job from warming the water earlier in spring. Use the published specifications alongside your pond’s heat requirement when choosing the model. Compare other models in our air source heat pump range, or explore the alternatives under pond heating.

Remora Professional 8 specifications

Heat output, air 27°C / water 27°C 4.2–8.6 kW
Heat output, air 15°C / water 26°C 2.4–5.75 kW
Electrical supply 230 V; supplied with a 2.8 m cable and UK plug
Nominal water flow 3–5 m³/hour
Dimensions, length × width × height 870 × 380 × 653 mm
Weight 43 kg
Control temperature range 5–40°C, according to application
Wi-Fi Built in; Smart Life app
Electrical input at A27/W27 0.48–1.21 kW
Electrical input at A15/W26 0.45–1.15 kW
COP at A27/W27 7.15–16.58
COP at A15/W26 5.02–8.16
Maximum current 7.5 A
Refrigerant R32
Published noise at 10 m Below 29 dB(A)
Water connections 1½ inch

Choosing it for a covered koi pond

If your aim is approximately 12°C through winter, tell us the pond volume, surface dimensions, construction, cover arrangement and location. Include any exposed filter chambers or long external pipe runs. Two ponds containing the same number of litres can lose heat at very different rates, so volume is a starting point rather than a complete sizing calculation.

The output figures above also show why the model name should not be treated as a guaranteed winter heating output. Published performance changes with the test conditions. Neither of those figures is a specific prediction for a cold night with the pond at 12°C. A winter recommendation needs to allow for the local conditions, heat loss and time spent defrosting. For a winter recommendation, provide the pond dimensions, cover details, location and target temperature so the heater can be matched to the heat loss.

For spring and autumn use, explain when you intend to start heating and the temperature you want to maintain. A heater selected for modest seasonal support may not have enough reserve for continuous winter duty or a higher target temperature. Resolve that choice before comparing purchase prices, as the most economical installation is one selected for the intended job.

Understanding inverter operation

Inverter control allows the compressor to vary its operation as demand changes. During a recovery period the system may need more output; closer to the target, it can reduce its output within its operating range. That does not make running cost a fixed number. Weather, heat loss, water temperature and the amount of heating required all influence electricity consumption.

Heat output and electrical input are different measurements. When comparing pumps, use figures measured under the same air and water conditions. A headline efficiency figure obtained in warm conditions should not be used to estimate the whole winter electricity bill. A pond cover and insulation should be considered alongside the heater rather than added as an afterthought.

Water flow and installation planning

Plan the water circuit so that the heater receives the specified flow. The circulating pump, pipe diameter, fittings and any bypass arrangement all affect what reaches the heat exchanger. Do not assume the pump’s advertised maximum flow is the flow through the installed heater. Include suitable isolation and service access so maintenance does not require dismantling the surrounding filtration.

Before ordering fittings, check the exact supplied union arrangement against the installation manual and the pipework already on your pond. Provide space to disconnect the water connections and to drain the equipment when necessary. A bypass can be useful for setting the heater branch flow and for servicing, but it must be arranged to suit the actual system.

Outdoor siting and electrical connection

Choose a firm, stable outdoor position that leaves the manufacturer’s required clearances around the unit. Keep the air inlet and discharge clear of close fencing, vegetation and stored equipment. Enclosing a heat pump without a designed airflow route can cause it to draw its own cooled discharge air back in, reducing its ability to collect heat.

Allow for condensate drainage as part of the installation. Water produced during normal operation needs somewhere suitable to go without creating a slippery path or collecting around the base. Leave enough access for inspection and cleaning, as well as for opening service panels.

The supplied plug does not remove the need for a suitable electrical installation. Use an appropriately protected outdoor supply and follow the exact manual. Have the circuit assessed where necessary, particularly if other equipment already uses it. Position cables and pipework so routine garden work cannot damage them.

Daily use, monitoring and winter care

Make temperature changes gradually and monitor the pond with a suitable thermometer. App access is useful for checking settings, but it is not a substitute for inspecting water circulation, the pond and the equipment. If the heater stops, investigate the cause and follow the fault guidance before changing settings repeatedly.

Keep the air path clear and inspect the drainage route regularly. If the heater will be taken out of service during freezing conditions, follow the manual’s draining and winterisation instructions. Switching the electrical supply off alone does not remove water trapped inside the heat exchanger. An idle unit and an actively heating installation require different winter arrangements.

Comparing the next model size

Compare the Professional 8 with the other sizes in the Remora Professional range. Look at the output under matching test conditions, the required flow and the electrical requirements, not simply the number in the model name. Contact us with your pond details if you need help choosing between sizes before placing an order.

Helpful pond heating guide

For more help choosing pond heating equipment and understanding running considerations, see our related guide:

Warranty and supplied fittings

The supplier lists four-year heater cover, with compressor and titanium-coil corrosion cover extending to ten years; after year four this is parts only. Frost damage is excluded.

Included fittings are water connection unions, rubber feet and a condensate hose with elbow, alongside the manual. A winter cover is included.

Check the supplier warranty and installation information for the full conditions. Follow the draining instructions whenever the unit is taken out of service in freezing weather.

Other heat pumps to compare

Compare nearby models and alternative ranges before choosing your heater.

Rated heating output is measured at the stated air and water temperatures. In these figures, A means air temperature and W means water temperature, both in degrees Celsius. Heating output is not electrical consumption or a guarantee of winter performance. For a koi pond, compare the minimum water setpoint and cold-weather output as well as the headline kW rating.

Electrical supply and UK socket connection

Maximum current: 7.5A.

Supplied with a 2.8m cable and UK plug, according to the UK supplier. It can connect to a suitable 13A UK socket with the protection and outdoor installation specified in the instructions.

Availability and delivery

Most of our heat pumps are kept in stock. Some models may be dispatched directly from our supplier, and availability can change. Please allow 1–2 weeks for delivery where additional lead time is needed. We will keep you informed of your order’s progress and expected delivery date. If you need your heat pump by a particular date, please contact us before ordering so we can confirm the current lead time.

Remora Professional 8 8.6kW Inverter Heat Pump with Wi-Fi Reviews

Reviews

There are no reviews yet.

Be the first to review “Remora Professional 8 8.6kW Inverter Heat Pump with Wi-Fi”