Oase ClearTronic 11 W Aquarium UVC Clarifier
| Brand | |
|---|---|
| UVC lamp | 11 W TC-S (UV-C) |
| Total draw | 14 W |
| Aquarium guide | Up to 600 litres |
| Clarifying flow | Up to 750 L/h; manual guidance |
| Hose size | 16 mm inner / 22 mm outer diameter |
Oase ClearTronic 11 W GB UVC clarifier, article 44249. 14 W total draw, 16/22 mm hose connections and an aquarium guide up to 600 L. Lamp included.
£86.68 (inc VAT)
The Oase ClearTronic 11 W is an external aquarium UVC clarifier for a suitable circulating water system. Water passes through its enclosed UVC chamber to help control suspended algae that cause green water. This GB version is manufacturer article 44249; it is a separate clarifier rather than a water pump or a complete aquarium filter.
What is supplied
One complete Oase ClearTronic 11 W GB clarifier, article 44249, with its UVC lamp, hose connections and operating instructions.
Plan the separately required water circulation, filtration and connecting hose. The listed hose size describes the connection, not a supplied length of hose or a universal promise that the unit fits every external filter.
Representative ClearTronic family photograph. This listing is for the 11 W GB model, article 44249.
Choose the model and match the flow
The 11 W model has the largest published aquarium and clarification-flow guides of these three ClearTronic units: up to 600 litres and 750 litres per hour. That is a step above the 9 W model’s 400 litres and 500 litres per hour. Check the actual water flow through the UVC chamber; choosing the larger lamp does not remove the flow or pressure limits.
The instructions distinguish two uses: up to 750 L/h for cloudy-water clarification and a separate 600 L/h guide for germ reduction. These are recommended flow limits, not a pump output or a guarantee of sterile water. Water condition, the actual flow and the condition of the lamp and quartz glass all affect performance.
A UVC clarifier works alongside filtration and sensible aquarium care. It does not physically collect debris, replace water testing or remove the need to investigate the cause of persistent cloudiness. Keep suitable mechanical and biological filtration in the system.
Connections and installation
Check both the 16 mm hose inner diameter and 22 mm outer diameter when planning the connection. The operating pressure must stay at or below 0.5 bar and the permitted water temperature is 4–35 °C. Compare those limits with the actual circuit, not only the maximum figure printed on a pump box.
Install the unit indoors and outside the aquarium, leaving room to remove the head for servicing. Follow the permitted mounting positions in the supplied instructions. The manual places the clarifier in the water circuit, ideally before a filter; follow the instructions for the complete filter and hose arrangement as well.
Start the water circulation first and check the connections for leaks before switching on the UVC unit. Protect plug connections from moisture and use an electrical supply protected by an RCD with a rated residual current of no more than 30 mA. The GB electrical specification is 230 V AC, 50 Hz.
UVC safety and routine care
UVC radiation can injure eyes and skin. Operate the lamp only in the correctly assembled, undamaged casing; never run an exposed lamp to check whether it works. Disconnect and isolate the unit from the electricity supply before opening it or carrying out maintenance. Do not use a unit with a damaged housing or cable.
Keep the quartz glass clean using the method in the instructions and handle both the glass and lamp carefully. The manual specifies lamp replacement after a maximum of 8,000 operating hours. For this model, compare the type plate with the 11 W lamp specification and Oase replacement article 56112; a similar-looking lamp is not enough to establish suitability.
If clarity falls, check the real flow, soiling on the quartz glass and lamp service history before assuming that a more powerful unit is the answer. The product is for aquarium water, not drinking-water treatment or commercial and industrial use.
Technical overview
| Detail | Specification |
|---|---|
| Manufacturer | Oase |
| Article | 44249 |
| Version | GB |
| Product type | Aquarium UVC clarifier |
| UVC lamp | 11 W TC-S (UV-C) |
| Total draw | 14 W |
| Aquarium guide | Up to 600 litres |
| Clarifying flow | Up to 750 L/h; manual guidance |
| Manual germ flow | Up to 600 L/h; conditional manual guidance |
| Hose size | 16 mm inner / 22 mm outer diameter |
| Electrical rating | 230 V AC / 50 Hz |
| Max pressure | 0.5 bar |
| Water temperature | 4–35 °C |
| Installation | Indoors; outside the aquarium |
| Water use | Freshwater and marine aquariums |
| Dimensions | 330 Ă— 120 Ă— 100 mm (L Ă— W Ă— H) |
| Net weight | 1.28 kg |
| Cable length | 1.5 m |
| Protection class | IP24 |
| Lamp service | Replace after a maximum of 8,000 operating hours |
| Replacement lamp | 56112 |
| Guarantee | 2 years, subject to manufacturer conditions |
| Supplied | Clarifier, UVC lamp, hose connections and instructions |
Common questions
Is the 11 W figure the total electrical consumption?
The 11 W model name identifies its UVC lamp. The whole GB unit has a total electrical rating of 14 W. Do not use the lamp figure as the complete unit’s power consumption.
Can I put the ClearTronic inside the aquarium?
No. This unit is installed indoors and outside the aquarium as part of the water circuit. Keep electrical plug connections dry and follow the permitted mounting positions in the instructions.
Does it include a pump and connecting hose?
This listing supplies the clarifier with its UVC lamp, hose connections and instructions. Arrange the separately required pump or filter circuit and suitable connecting hose; no complete filtration or hose bundle is specified.
Will it make the aquarium water germ free?
No germ-free or fish-health guarantee is made. The manual’s separate low-flow guidance does not replace filtration, maintenance, water testing or other appropriate aquarium care.
When does the UVC lamp need replacing?
The manual specifies replacement after a maximum of 8,000 operating hours. Use the correct 11 W lamp specification and check replacement article 56112 against the unit type plate and instructions.
Compare aquarium filters and filter media, browse external aquarium filters, and keep suitable water care and testing alongside your UVC setup.



Reviews
There are no reviews yet.