Hanna HI98108 pHep+ pH and Temperature Tester
| Brand | |
|---|---|
| Model | HI-98108 |
| pH range | 0.00–14.00 pH |
| Resolution | 0.01 pH |
| pH accuracy | ±0.10 pH at 25°C |
| Calibration | Automatic; follow the supplied model manual |
| Electrode | Check the exact supplied revision and maintenance instructions |
| Temperature | 0.0–50.0°C;0.1°C resolution;±0.5°C accuracy |
The HI98108 pHep+ measures pH and sample temperature. Its pH range is 0.00–14.00, with a 0.01 pH display step and ±0.10 pH accuracy.
£94.50 (inc VAT)
Hanna HI98108 pHep+ pH and Temperature Tester
A direct reading from a pH electrode
The HI98108 pHep+ measures pH and sample temperature. Its pH range is 0.00–14.00, with a 0.01 pH display step and ±0.10 pH accuracy.
| Specification | Details |
|---|---|
| Model | HI98108 |
| pH range | 0.00–14.00 pH |
| Display resolution | 0.01 pH |
| pH accuracy | ±0.10 pH at 25°C |
| Calibration | Automatic; follow the supplied model manual |
| Electrode | Check the exact supplied revision and maintenance instructions |
| Temperature measurement | 0.0–50.0°C;0.1°C resolution;±0.5°C accuracy |
Choosing the tester
Use the supplied manual for the automatic calibration sequence and the buffer values it recognises. Keep its instructions with the tester so the same method can be repeated during later checks.
pH and alkalinity are different measurements. For freshwater buffering capacity, see the HI775 alkalinity Checker. Keeping both readings clearly labelled is more useful than trying to compare their numbers directly.
Calibration and electrode care
Calibrate with fresh buffers recognised by the instrument, choosing the points for your expected measuring range. See pH 4.01 and 7.01 buffer sachets and check whether your method requires other buffer values.
Keep the electrode clean and store it as instructed. HI7061M general cleaning solution and HI70300M storage solution do different jobs; use the product specified for the probe and follow the relevant method.
Taking repeatable pond readings
Use a representative sample and wait for the reading to stabilise as the manual directs. Record the time and the temperature where available, so you can compare later measurements on a useful basis.
A pocket sample tester is used for spot checks. Choose a suitable monitoring system if your routine needs readings or alerts between visits.
Compare related equipment
Compare the Hanna Pocket pHep4 Water-Resistant pH Tester – HI-98127 and browse Hanna alkalinity and pH equipment. Send us the full model and electrode code if you would like help matching care supplies.