Charles Austen VB1200G Side Channel Blower

SKU: VB1200G
Brand

Air Flow

1317 L/min

Air Pressure

0.19 bar

Power

600 W

Charles Austen VB1200G Side Channel Blower: oil-free side-channel blower for commercial aeration and treatment installations that require high-volume air delivery. Maximum output 1317 L/min. Published pressure 0.19 bar. Rated power 600 W. Supplied by Charles Austen.

£285.99 (inc VAT)

Charles Austen VB1200G Side Channel Blower

Charles Austen VB1200G Side Channel Blower is an oil-free side-channel blower intended for commercial aeration and treatment installations that require high-volume air delivery. Its published maximum output is 1317 L/min at up to 0.19 bar, using 600 W. This page identifies the exact model, duty figures and selection limits so it can be compared accurately with the other products in the range.

Charles Austen is both the product brand and supplier. The figures below come from the current 2026 supplier catalogue, supported by manufacturer guidance where a current technical page is available. Maximum figures are not the same as guaranteed installed performance: pipework, depth, pressure, media loading and maintenance all affect the result.

Who is the VB1200G best suited to?

This model is best considered for commercial aeration and treatment installations that require high-volume air delivery. It sits 4 of 6 when the range is ordered by nominal output/capacity. That makes it easier to judge whether it is a compact entry model, a mid-range choice or one of the higher-output options before comparing price alone.

Key product features

  • High-volume oil-free airflow for commercial aeration
  • Suitable for treatment, aquaculture, agitation and air-movement duties
  • Pressure and airflow stated at the model level
  • Single-phase and professional blower formats represented in the range
  • Exact SKU and manufacturer part number: VB1200G.
  • Supplied through Charles Austen and linked to compatible models for easier range comparison.

Technical specification

Model / MPN VB1200G
Product type oil-free side-channel blower
Supplier Charles Austen
Brand Charles Austen
Series Side Channel Blowers
Maximum air output 1317 L/min
Maximum pressure / stated duty pressure 0.19 bar
Power 600 W
Energy at 24-hour operation 14.40 kWh per day (calculated from rated wattage)
Installation format Engineered external installation with relief protection and appropriate electrical work
Range position 4 of 6 when the range is ordered by nominal output/capacity
Catalogue specification 1317 L/min 0.19 bar 600W

Technical figures are nominal supplier ratings. The calculated 24-hour energy figure, where shown, is rated wattage × 24 hours and does not include tariffs or intermittent thermostat operation.

Understanding the published specification

Airflow and pressure must be read together. The published 1317 L/min is paired with 0.19 bar; the installed airflow will be lower if the pump has to overcome greater water depth, a restrictive diffuser, narrow airline, long pipe runs, non-return valves or a heavily throttled manifold. Pressure is not an optional extra specification: it is what enables the air to reach the diffuser and pass through its membrane or pores.

The catalogue specification for this exact model is 1317 L/min 0.19 bar 600W. Where the page includes a calculated daily-energy figure, it is provided only to make continuous-running products easier to compare; it is not an electricity-cost estimate and does not replace the rated power shown above.

How to size this model correctly

A side-channel blower must be selected against a system curve. Include diffuser back pressure, water depth, pipe friction and valve losses, and fit the pressure-relief equipment specified by the supplier.

For critical livestock, treatment or commercial systems, allow spare capacity and consider redundancy. If the required duty is close to the model’s maximum, moving to the next size normally provides a more useful operating margin than running a smaller unit continuously at its limit.

Installation and commissioning

Installation format: Engineered external installation with relief protection and appropriate electrical work. Keep access available for cleaning and servicing, use appropriately sized hoses or airline, and avoid unnecessary bends or restrictions. Aquatic electrical equipment should be protected by a suitable RCD and installed in accordance with the supplied instructions.

After installation, check every outlet for a stable bubble pattern and listen for a change in pump tone. A branch with weak output may be restricted or longer than the others, while a pump that becomes noticeably louder or hotter can be working against excessive back pressure.

Commission the complete system by checking actual flow, pressure, water level or temperature at the point of use rather than assuming the headline maximum will be achieved. Recheck after filters, diffusers or pipework have had time to accumulate normal fouling.

Compatible system components

For pond, treatment and multi-outlet work, size the diffuser area and manifold for the whole pump output. Dividing a pump across several balanced branches usually gives a more even air pattern than forcing all output through one small diffuser. Use the largest practical airline bore, keep branches similar in length and provide a safe route for surplus air rather than closing most manifold outlets.

Compatibility should be confirmed from the complete installation: connection size, hose or airline bore, voltage, control method, permitted flow and future servicing access can all affect whether two individually suitable products work correctly together.

Maintenance and service life

Maintain clean intake filtration, unrestricted cooling and a safe relief path. Installation and servicing should be handled by a competent engineer familiar with blower systems.

Record the installation date and normal operating performance. A visible reduction in output, increasing noise, rising temperature or repeated tripping should be investigated rather than compensated for by restricting or altering other parts of the system.

Performance checks and fault finding

If airflow falls, test the system methodically: inspect the intake, disconnect the manifold to compare unrestricted output, check the airline for leaks or kinks, and clean or replace fouled diffusers. Only diagnose internal pump wear after external restrictions have been ruled out. For critical aeration, keep a contingency pump or alternative oxygen source available during servicing.

Compare any suspected fault with the clean, newly commissioned condition. Changes across every outlet or return normally point to the main unit or a shared restriction; a problem affecting one branch is more likely to be local pipework, airline, a valve, diffuser or connected accessory.

Compare similar commercial blowers

The table below links to five nearby models so the buyer and search crawler can move through the range without returning to a search page.

Model Key published duty Product type
VB800G 1000 L/min · 0.15 bar · 400 W Side Channel Blower
SCB2100 100 m³/hr · 100 m · 700 W Side Channel Blower
SCB2145 145 m³/hr · 145 m · 700 W Side Channel Blower
VB390G 500 L/min · 0.1 bar · 110 W Side Channel Blower
VB290G 350 L/min · 0.09 bar · 120 W Side Channel Blower

Complete the system and explore the range

The supplier and customer-facing brand for this listing is Charles Austen. The links below connect this model to its dedicated range, relevant system components and the wider Charles Austen catalogue.

Technical information sources

Core model figures were checked against the current 2026 Charles Austen supplier catalogue. Family features, installation points and application guidance were cross-checked against current manufacturer technical material where available.

Charles Austen VB1200G Side Channel Blower Reviews

Reviews

There are no reviews yet.

Be the first to review “Charles Austen VB1200G Side Channel Blower”