TMC V2PowerPad 400 Calcium and Magnesium Pad

SKU: TM5970
Brand

Fits

TMC V2PowerBox 400

Media type

Calcium and Magnesium Pad

One TMC calcium and magnesium V2PowerPad sized for the V2PowerBox 400.

£10.19 (inc VAT)

A calcium and magnesium insert for the larger V2PowerBox

Choose this TMC V2PowerPad for the calcium and magnesium stage in a compatible marine V2PowerBox 400. The larger pad matches the 400 compartment. Check the aquarium’s levels and what other products you use before fitting it, then follow the pad guidance and keep testing.

Decide if combined supplementation suits the system

An aquarium with an external PowerBox 400 may also have a sump, several circulation pumps or a dosing schedule already in use. Start by listing what adds calcium and magnesium and where it enters the system. Look back at recent readings, saltwater changes and livestock changes. If you are adding media to only one of several filters, record that position so the next person servicing the setup knows where the supplement is running.

Measure each mineral before changing the routine. For example, select the Salifert marine calcium test and Salifert magnesium test separately. Use a consistent place and time to take a sample after the aquarium water is well mixed. Match readings to the actual aquarium chemistry and the requirements of the livestock.

Check the model and media compartment

Read the filter label and match V2PowerBox 400 and TMC article 5970 before ordering. The model number identifies the filter, even if the canister has been moved to a different aquarium. Keep the original media layout available when you service an older filter. A photograph of the trays before you lift them out makes it easier to return the existing stages to the same order.

Check the part on the filter body if more than one canister is used. TMC lists a dedicated 400 fit for 5970. Its number describes the fit. The maker evidence gives no rate of mineral addition for a 400-litre display or any other volume.

Follow the instructions for isolating and opening the external filter. Keep established biological media wet in aquarium water while you work. Seat the pad in the position shown for your filter and check that the tray can close without being forced. TMC asks for good water flow through the pad. When the filter is back together, prime it as instructed and check the return and connections before leaving it running.

Allow for water changes and existing dosing

Corals and other calcifying animals can consume minerals at different rates as the stock changes. A change of salt or salinity can also affect a test result. Look at the recent history before attributing a difference to depletion. If both minerals need support, use the pad as directed and monitor them separately. If one is already appropriate, consider a product with a labelled single-mineral dose for the other.

Choose an individually measured product when independent control of the two levels matters. For example, the Salifert Liquid Magnesium one-litre listing covers one mineral and has its own dosing instructions. Use the directions for whichever exact product you choose. The 5970 article does not come with a verified numerical release rate that you can subtract from a regular liquid dose.

Keep a note when you change any other setting at service. If you replace the pad on the same day you prepare a large water change, for example, the next mineral reading may reflect both events. Recording the sequence and allowing the system to mix helps you decide whether your routine is still appropriate.

Check flow and set a service date

TMC’s published V2PowerPad range guidance is to replace the pad at four weeks or earlier if needed and to use it with regular water testing. Check the individual label and reassess the tank’s mineral readings before opening another pad.

Inspect the PowerBox’s own flow if other equipment is moving the display water. Check the 400’s fittings and return after restart and confirm water is passing through the intended media arrangement. Reassess tray fit if flow changed as soon as you added the pad.

A drop in calcium or magnesium is a reason to review the testing and dosing record. It is not a direct measure of how much of a pad remains. At each review, consider whether the current stocking and schedule still justify a combined source before you add a fresh one.

Compare other models and the media you already have

If the filter is a different PowerBox, choose the 200 calcium and magnesium pad or the 100 Nano calcium and magnesium pad to match it. These articles differ by host filter fit. Match the purpose separately if you need other media for the same filter. See aquarium water care and testing for the measurement side of the setup.

Technical overview

Feature Details
Manufacturer / article Tropical Marine Centre 5970
Fit TMC V2PowerBox 400 media compartment
Function Calcium and magnesium supplementation
Pack One pad
Water type For measured marine supplementation. Confirm any other application from the label.
Service Four weeks or earlier if needed under TMC range guidance. Review readings before replacing.

Frequently asked questions

How does 5970 compare to the MicroHabitat pack?

Article 5970 is one calcium and magnesium pad for the PowerBox 400. The MicroHabitat 15 and 30 use a chamber-specific pair of pads with a separate trace-element piece, under article 5979.

What do I get and how much does it add?

The pack contains one pad. TMC identifies the mineral types it supplies and specifies the filter fit. The published article evidence gives no milligrams per pad or fixed change in concentration. Follow the pack label and use repeat measurements.

When should I test again after fitting?

Choose a consistent testing routine suited to the tank and check after changes. Note salinity, when the sample was taken and other supplements. Review the trend before changing the pad or layering another mineral product into the system.

How should I record the pad in a larger system with a dosing pump?

Write down that the 5970 is in the PowerBox 400, the date and what you were trying to correct. Note the separate dosing schedule and keep a record of any water changes between tests. Use those notes when assessing the next calcium and magnesium results. If another person services the canister, pass on which compartment contains the mineral pad and the reason to leave, change or remove it. This avoids an unintended dosing change at routine filter service.

TMC V2PowerPad 400 Calcium and Magnesium Pad Reviews

Reviews

There are no reviews yet.

Be the first to review “TMC V2PowerPad 400 Calcium and Magnesium Pad”