TMC V2PowerPad 400 Ammonia Reduction Pad

SKU: TM5973
Brand

Fits

TMC V2PowerBox 400

Media type

Ammonia Reduction Pad

One TMC ammonia reduction V2PowerPad for the V2PowerBox 400 media compartment.

£10.19 (inc VAT)

Ammonia reduction media sized for the V2PowerBox 400

Choose the TMC 400 pad for a matching V2PowerBox 400 when you’re addressing a measured ammonia reading and the pad suits that water. Fit it as directed without disturbing established biological media. Check the water as part of the ongoing response rather than relying on a calendar alone to decide what needs attention.

Check the 400 and the rest of the system

A larger aquarium may have two filters, a sump or separate circulation pumps. Movement at the surface can come from another unit even when the 400 has lost its return. Check the outlet that belongs to the PowerBox. If several filters were cleaned or disconnected together, note what happened to each biological stage and when normal flow came back.

If ammonia is measurable in a stocked aquarium, review the results alongside the livestock and other water readings. Use a suitable method for the water type, such as the freshwater Aquarium Lab Multi Test Kit or Marine Lab ammonia kit. Keep a record of the time and conditions of each test. Seek appropriate help promptly if the livestock show distress or water quality remains poor.

Check the model and media compartment

Read the filter label and match V2PowerBox 400 and TMC article 5973 before ordering. The model number identifies the filter, even if the canister has been moved to a different aquarium. Keep the original media layout available when you service an older filter. A photograph of the trays before you lift them out makes it easier to return the existing stages to the same order.

Match the printed 400 model and pad article before opening the filter. If you service several canisters in one cabinet, identify the inlet and return for this unit. Its PowerPad is fitted to the media compartment, while other canisters or sump media holders have their own parts.

Follow the instructions for isolating and opening the external filter. Keep established biological media wet in aquarium water while you work. Seat the pad in the position shown for your filter and check that the tray can close without being forced. TMC asks for good water flow through the pad. When the filter is back together, prime it as instructed and check the return and connections before leaving it running.

Separate ammonia reduction from restoring normal filtration

Ammonia reduction media can form part of the response when a correctly interpreted test shows a rise. Check for an ongoing cause such as waste accumulation, a power interruption, disrupted filtration or increased load. Once normal flow has been restored, the readings still need to show how the system is coping. A working pump is only one part of biological filtration.

TMC gives no per-pad load or a removal rate tied to a nominal tank volume. Conditions in a heavily stocked aquarium differ from those after an isolated interruption. The PowerBox label is the fit check. Choose a response to the aquarium’s actual readings rather than trying to work out a fixed removal percentage from the number on the filter.

The 400 has a separate 5958 filtration start-up article for maturation. It also has water clarity formulations for fine particles. Water testing tells you about ammonia independently of the appearance of the water. Record what has changed in the system and leave established media in place while you address the water problem.

Check flow and set a service date

TMC’s published V2PowerPad range guidance is to replace the pad at four weeks or earlier if needed and to use it with regular water testing. Water readings and system conditions guide when an earlier check is needed.

Write down which canister received the 5973, where the pad sits and when it went in. Keep observing the 400’s flow even if another unit maintains circulation. Inspect for debris and use the filter’s instructions to service the normal mechanical stage promptly when return flow changes.

At later checks compare ammonia and nitrite with the maintenance record, any water changes and changes in feeding. Keep the established media wet if you open the filter again. After removing a temporary reduction stage, follow test results to see how the permanent filter responds to the ordinary load.

Find the matching part if you have another canister

Choose the 200 ammonia reduction pad or 100 Nano ammonia reduction pad if you have those filters. The part numbers reflect a change in canister fit. If the job is ongoing measurement, see the aquarium water care and testing range to choose a kit for the correct water type.

Technical overview

Feature Details
Manufacturer / article Tropical Marine Centre 5973
Fit TMC V2PowerBox 400 media compartment
Function Ammonia reduction
Pack One pad
Water type Follow the exact pad label for water-type suitability
Service TMC advises four weeks or earlier if needed. Continue testing during use.

Frequently asked questions

Can I choose the 400 pad as an upgrade for a smaller filter?

TMC gives the 5973 a PowerBox 400 fit. Use the correct part for the smaller model so media can sit in the intended position and water can move through the case correctly.

Should I change other media while I fit it?

Keep the established biological stages operating while you investigate the source of the ammonia reading. If you have more than one canister and must service one, log which unit is opened and confirm its own return after restarting. Manage necessary changes according to the filter instructions and the condition of the aquarium.

How long will the pad keep reducing ammonia?

TMC’s general pad service interval is four weeks or earlier if required. Use regular tests and check the cause of a rise. The calendar interval gives no guarantee of remaining capacity, and the timing depends on the actual aquarium and its filter.

Can I use it to replace permanent biological media?

Keep the established biological stage in service. It provides the ongoing waste-processing capacity of the canister. The 597-series pad is an additional medium chosen for ammonia reduction, and its use should be reviewed with water tests and the pack instructions.

What if ammonia rises again after I remove the pad?

Repeat the test and check the flow from each filter. Look for a continuing source of waste or a problem with the biological stages. A recurrence is a reason to review the whole system, including any other canister that was recently serviced.

TMC V2PowerPad 400 Ammonia Reduction Pad Reviews

Reviews

There are no reviews yet.

Be the first to review “TMC V2PowerPad 400 Ammonia Reduction Pad”