PVC Imperial Pressure Pipe Reducers
| Size | 1″–3/4″, 1.5″–1″, 2″–1″, 2″–1.5″, 3″–2″, 4″–2″, 4″–3″, 2.5″–1.5″, 2.5″–2″ |
|---|---|
| Material | PVC |
| Pipe system | Imperial pressure pipe |
| Connection type | Plain reducing bush |
Plain PVC reducing bushes for compatible imperial pressure fittings. Choose the larger socket and smaller pipe size as a pair, from 1″–¾″ to 4″–3″, including 2½″–1½″ and 2½″–2″. One bush; pipe and cement separate.
£3.72 (inc VAT)
PVC Imperial Pressure Pipe Reducers
These plain PVC reducing bushes let you step down between selected sizes of imperial pressure pipe fittings. The larger outside of the bush fits into a matching plain socket, while the smaller internal socket accepts the corresponding smaller pipe. They are useful when planning a pond filter bay, adapting a branch or making a specified transition between two sections of rigid plumbing.
Choose the complete size pair rather than ordering by the larger size alone. A 2 inch to 1 inch bush and a 2 inch to 1½ inch bush fit the same nominal larger socket but accept different smaller pipes. Each selection supplies one reducing bush. Pipe, larger socket fittings, solvent cement and cleaning materials are separate.
Size options
| Larger socket size | Smaller pipe size |
|---|---|
| 1 inch | ¾ inch |
| 1½ inch | 1 inch |
| 2 inch | 1 inch |
| 2 inch | 1½ inch |
| 2½ inch | 1½ inch |
| 2½ inch | 2 inch |
| 3 inch | 2 inch |
| 4 inch | 2 inch |
| 4 inch | 3 inch |
These are nominal imperial pressure-pipe sizes. They do not describe the measured outside diameter of the entire fitting. Check the markings and connection specifications of the pipe and receiving socket before making a permanent joint. The bush needs the correct mating socket on its larger side; it is not simply a sleeve that joins the bare ends of any two different pipes.
Choose the correct pipe system
Imperial pressure pipe, metric pressure pipe and waste pipe use different connection conventions. A similar description or a close measurement does not guarantee a solvent-weld fit. Do not force a bush into the wrong socket or fill a loose fit with extra cement. The mating dimensions must be appropriate for the selected components.
Use these bushes with compatible imperial pressure pipe and matching plain fittings. If the job involves changing between pressure and waste pipe, compare our pressure-to-waste reducing bushes. Where the change is specifically between imperial and metric pressure connections, see our imperial-to-metric pressure bushes. Those are separate transitions and should not be substituted just because their names include the word reducer.
Think about the flow before reducing a pipe
A reducer changes the connection size; it does not preserve the hydraulic capacity of the larger pipe. The smaller section, the length of the run and other fittings all contribute to the resistance the pump must overcome. Check the pump and filter installation requirements before reducing an inlet or outlet, especially where the equipment specifies a minimum pipe size.
It can be helpful to draw the whole run before buying fittings, including valves, unions, bends and branch connections. That makes it easier to see whether a reduction is genuinely needed or whether using a consistent pipe size would be more practical. Do not size a gravity-fed line simply by copying the diameter used on a pressurised pump outlet.
Preparing a solvent-weld joint
Check that the pipe ends, bush and receiving socket are undamaged and compatible. Cut pipe square and remove burrs. Prepare the surfaces and insertion marks as directed by the adhesive manufacturer, taking care to keep dirt and standing water away from the joint. Assemble the layout for checking before applying cement, rather than discovering an alignment problem after the joint has begun to set.
Use an appropriate PVC solvent cement and any specified cleaner or primer. Follow the instructions for the particular product, pipe size and working conditions. Cement is not a general filler for cracked fittings, large gaps or the wrong pipe system. If a component is damaged or does not fit correctly, replace it before continuing.
Allow access for future maintenance
A solvent-welded reducing bush becomes part of a permanent assembly. Think about where you will disconnect the pipework when a pump, valve or filter needs attention. Adding a suitable pressure pipe union at the planning stage can avoid the need to cut a run later. Leave room to loosen union nuts and remove the equipment they serve.
Support the pipework so the reducer is not carrying the weight of a long unsupported run. Keep pipe connections aligned instead of drawing them together under tension. A tidy layout is useful, but access and sound support matter more than forcing several components into the smallest possible space.
Curing and checking the completed installation
Leave each joint undisturbed for the period specified by the solvent-cement manufacturer. The correct wait before filling or pressurising depends on the adhesive and installation conditions, so a universal cure time is not given for this fitting. A joint that feels firm on the outside may still need more time before service.
After the required cure period, introduce water gradually and inspect both sides of the transition. Check again with the system operating, watching for leaks and movement. If there is a problem, isolate and drain the section before investigating; coating the outside of a leaking joint is not a substitute for making the connection correctly. For a threaded size change, use a suitable BSP threaded reducer instead of treating a plain bush as a threaded fitting.



Reviews
There are no reviews yet.