Hanna Panel Mounted Dissolved Oxygen Controller – HI-8410

SKU: HI-8410
Brand

Model

HI-8410

Measurement range

0.0–50.0 mg/L; 0–600% oxygen saturation

Resolution

0.1 mg/L or 1% saturation

Oxygen accuracy

±1% of reading at 20°C

Calibration

Manual, one point in saturated air

Recorder output

Isolated 0–20 mA or 4–20 mA

Panel cutout

141 × 69 mm

Control modes

OFF / AUTO / ON

Panel-mounted dissolved-oxygen controller with setpoint, alarm and analogue output functions. Requires the specified HI76410 galvanic process probe and a suitable installation.

£1,007.41 (inc VAT)

Hanna HI8410 Panel-Mounted Dissolved Oxygen Controller

A fixed monitoring and control installation

The HI8410 is a panel-mounted dissolved-oxygen controller. With the correct external galvanic probe and control installation, it can monitor oxygen and operate its setpoint and alarm functions. It is not a complete portable meter or an aerator.

The controller is supplied with mounting brackets and instructions. The oxygen probe is a separate requirement, as are the equipment and electrical installation needed to act on the control output.

Specification Details
Measurement range 0.0–50.0 mg/L; 0–600% oxygen saturation
Resolution 0.1 mg/L or 1% saturation
Oxygen accuracy ±1% of reading at 20°C
Probe family in original manual HI76410/4 or HI76410/10, not included
Calibration Manual, one point in saturated air
Recorder output Isolated 0–20 mA or 4–20 mA
Panel cutout 141 × 69 mm
Control modes OFF / AUTO / ON

Match the probe and the installation

The original HI8410 manual specifies the HI76410 galvanic process-probe family. Match that complete reference, cable length and wiring arrangement to the actual controller. Do not assume a portable-meter probe with a similar name is interchangeable.

A qualified installer should confirm the supply voltage, relay loading, panel protection and the interface to the controlled equipment. The transparent front cover provides splash protection; it is not an instruction to install the controller unprotected beside the water.

Setpoints and checks

Agree the oxygen setpoint, alarm and operating response for the particular system. Calibration, membrane care and independent checks remain necessary; the presence of a controller does not guarantee that the pond is adequately aerated.

For portable spot checks, compare the HI9147-10 oxygen meter. For combined pH, conductivity and oxygen records, see the HI98194 multiparameter meter.