Hanna Panel Mounted Dissolved Oxygen Controller – HI-8410
| Brand | |
|---|---|
| Model | HI-8410 |
| Measurement range | 0.0–50.0 mg/L; 0–600% oxygen saturation |
| Resolution | 0.1 mg/L or 1% saturation |
| Oxygen accuracy | ±1% of reading at 20°C |
| Calibration | Manual, one point in saturated air |
| Recorder output | Isolated 0–20 mA or 4–20 mA |
| Panel cutout | 141 × 69 mm |
| Control modes | OFF / AUTO / ON |
Panel-mounted dissolved-oxygen controller with setpoint, alarm and analogue output functions. Requires the specified HI76410 galvanic process probe and a suitable installation.
£1,007.41 (inc VAT)
Hanna HI8410 Panel-Mounted Dissolved Oxygen Controller
A fixed monitoring and control installation
The HI8410 is a panel-mounted dissolved-oxygen controller. With the correct external galvanic probe and control installation, it can monitor oxygen and operate its setpoint and alarm functions. It is not a complete portable meter or an aerator.
The controller is supplied with mounting brackets and instructions. The oxygen probe is a separate requirement, as are the equipment and electrical installation needed to act on the control output.
| Specification | Details |
|---|---|
| Measurement range | 0.0–50.0 mg/L; 0–600% oxygen saturation |
| Resolution | 0.1 mg/L or 1% saturation |
| Oxygen accuracy | ±1% of reading at 20°C |
| Probe family in original manual | HI76410/4 or HI76410/10, not included |
| Calibration | Manual, one point in saturated air |
| Recorder output | Isolated 0–20 mA or 4–20 mA |
| Panel cutout | 141 × 69 mm |
| Control modes | OFF / AUTO / ON |
Match the probe and the installation
The original HI8410 manual specifies the HI76410 galvanic process-probe family. Match that complete reference, cable length and wiring arrangement to the actual controller. Do not assume a portable-meter probe with a similar name is interchangeable.
A qualified installer should confirm the supply voltage, relay loading, panel protection and the interface to the controlled equipment. The transparent front cover provides splash protection; it is not an instruction to install the controller unprotected beside the water.
Setpoints and checks
Agree the oxygen setpoint, alarm and operating response for the particular system. Calibration, membrane care and independent checks remain necessary; the presence of a controller does not guarantee that the pond is adequately aerated.
For portable spot checks, compare the HI9147-10 oxygen meter. For combined pH, conductivity and oxygen records, see the HI98194 multiparameter meter.