Hanna Iris Spectrophotometer – HI-801-02
| Brand | |
|---|---|
| Model | HI-801-02 |
| Wavelength range | 340–900 nm |
| Wavelength accuracy | ±1.5 nm |
| Spectral bandwidth | 5 nm |
| Photometric range | 0.000–3.000 Abs |
| Light source | Replaceable tungsten-halogen lamp |
| Sample formats | Supported round, square and rectangular cuvettes and 13 mm vials, with the correct adapters |
| Data export | CSV and PDF; USB connections |
| User-developed methods | Up to 100 |
Iris spectrophotometer with 340–900 nm wavelength selection, programmed and user methods, USB export and rechargeable battery.
Supplier orders: Hanna Instruments currently estimates around two weeks for direct supplier delivery; timing is subject to supplier confirmation.
£4,008.00 (inc VAT)
Hanna HI801-02 Iris Spectrophotometer
A selectable-wavelength laboratory instrument
The HI801-02 Iris uses a split-beam optical system and selectable wavelengths from 340 to 900 nm for programmed and user-developed sample methods. It measures transmittance, absorbance or the concentration produced by the selected validated method.
The HI801 uses its selected method and cuvette arrangement for each measurement. If automated identification of supported reagent vials is part of your intended workflow, compare the separate HI802 barcode-reader model.
| Specification | Details |
|---|---|
| Wavelength range | 340–900 nm |
| Wavelength selection step | 1 nm |
| Wavelength accuracy | ±1.5 nm |
| Spectral bandwidth | 5 nm |
| Photometric range | 0.000–3.000 Abs |
| Light source | Replaceable tungsten-halogen lamp |
| Sample formats | Supported round, square and rectangular cuvettes and 13 mm vials, with the correct adapters |
| Data export | CSV and PDF; USB connections |
| User-developed methods | Up to 100 |
Plan the whole test method
Choose the parameter, concentration range, reagent method and sample preparation before buying a spectrophotometer. Some analyses need additional apparatus or a digestion stage. The instrument’s wavelength range alone does not establish that an arbitrary sample can be measured accurately.
Factory methods and reagent-addition options can change with firmware. Match the installed method version, correct vial or cuvette and manufacturer instructions. Do not assume every method uses a sealed vial or that all required reagents are supplied with the instrument.
Cuvettes, power and supplied equipment
The manufacturer package includes sample cuvettes and adapters, cloth, scissors, USB cable and drive, power adaptor and documentation. A rechargeable battery supports portable use. Confirm the current package and the adapters required by your methods.
Keep the outside of each cuvette clean and follow its orientation or vial procedure. Optical checks and calibration records do not replace correct sampling, blanks and reaction times.
For a more focused benchtop photometer, compare the HI83300-02 and its installed method library.