Hailea HC-2200BH Water Chiller

SKU: HC2200BH
Brand

Heating Product Type

Water chiller / temperature controller

Heating Output

approximately 1491W when running

Control Type

electronic digital temperature display / controller

Best Use

aquariums, koi holding systems, hydroponics and specialist systems needing stable water temperature

Installation Type

External in-line installation

Connection Size

32mm hose tails

Hailea HC Series – HC2200BH is a Hailea water chiller for stable aquatic, hydroponic or specialist water temperature control. This page explains the suitable use, temperature stability benefits, flow guidance and key technical points in a clearer format.

£943.00 (inc VAT)

Hailea HC-2200BH Water Chiller

HC Series water chiller for stable aquatic and process temperature control

The Hailea HC-2200BH Water Chiller is a Hailea HC Series water chiller designed to maintain stable water temperatures in aquariums, hydroponic nutrient tanks, aquatic holding systems and specialist water temperature control. It is suited to systems up to around 2000 litres, with a $11,000 to 3,000 litres per hour.

Stable water temperature is often overlooked, but it can be critical in specialist aquatic systems. Fish, filtration bacteria, hydroponic crops, coral, laboratory equipment and temperature sensitive processes can all suffer when water becomes too warm or fluctuates heavily. A properly sized chiller helps remove excess heat and maintain a controlled environment.

The HC Series is built for dependable temperature regulation. It uses digital temperature control for straightforward adjustment and monitoring, with titanium evaporator for corrosion resistance in aquatic environments. This makes it suitable for demanding installations where long term reliability is more important than simply choosing the cheapest cooling option.

When to use a water chiller

A chiller is useful where ambient room temperature, lighting, pumps, filtration equipment or surrounding weather cause the water to rise above the preferred range. In aquariums and holding systems, excess heat can reduce dissolved oxygen and stress fish. In hydroponics, warm nutrient solution can affect oxygen availability and root health. In laboratory and industrial setups, temperature instability can reduce repeatability and reliability.

The right chiller should be chosen by water volume, heat load, desired temperature reduction, room temperature, flow rate and installation layout. The system volume shown on a product information is a useful guide, but actual performance depends on real conditions. A system exposed to strong sunlight, warm air or high heat input may need a larger chiller than the nominal volume suggests.

Installation and flow guidance

This model should be installed with a pump capable of providing the $11,000 to 3,000 litres per hour. Too little flow can reduce efficiency and trigger temperature instability, while too much flow may not allow the unit to exchange heat effectively. Use suitable hose or pipework, avoid unnecessary restrictions and make sure the chiller can be accessed for cleaning and maintenance.

Good ventilation is important. A chiller removes heat from the water and releases it into the surrounding air, so it should not be boxed into a sealed cupboard or placed where warm exhaust air is immediately drawn back into the unit. Allow space around the unit and keep intake and outlet areas clear.

Technical information

  • Type: HC Series water chiller / heater temperature controller
  • Model: HC2200BH
  • Water volume guidance: Up to around 2000 litres
  • Flow range: 1,000–3,000 L/h
  • Connector: 32mm hose tails
  • Cooling / high output class: approximately 1800W output class
  • Electrical input: approximately 1491W when running
  • Refrigerant: R134a
  • Heat exchanger: Titanium
  • Dimensions: 634mm x 468mm x 590mm
  • Weight: approximately 47kg
  • Temperature control: Digital display / electronic control
  • Heating note: HC2200BH can heat up to around 46°C as well as chill

Key benefits

✔ High-Capacity Cooling – Controls water temperature in systems up to 2000L
✔ Titanium Evaporator – Anti-corrosive and built to withstand saltwater and continuous use
✔ Digital Display – Clear, real-time monitoring and adjustments for precision control
✔ Quiet Operation – Low-noise design despite high performance
✔ Safety Features – Overheat protection and auto shutdown to safeguard system and livestock
✔ Versatile Applications – Perfect for aquariums, hydroponics, ponds, aquaculture, and commercial facilities

Installation and temperature control advice

A water chiller must be sized around the water volume, heat load, required temperature and the environment it is installed in. Flow rate is important, but so is ventilation. A chiller that cannot reject heat properly will struggle, even if the water flow through the unit looks correct.

Install the unit where it can breathe, where filters can be cleaned and where the display and pipe connections remain accessible. Keep pipework tidy, avoid unnecessary restriction and check the system regularly during warm weather. Stable temperature control depends on the full installation, not just the chiller model.

Related temperature control and pond equipment

Water temperature control should be planned alongside oxygenation, filtration and circulation. Cooler water can hold more dissolved oxygen, but fish, bacteria, plants and specialist aquatic systems still need stable circulation and good water movement to remain healthy.

If you are considering a chiller for a pond, aquarium, holding vat or hydroponic system, it is worth checking the actual heat load before ordering. Water volume is only one factor. Pump heat, sunlight, ambient air temperature and target temperature all affect the size of chiller required.

Professional setup advice

For best results, do not choose aeration, circulation or temperature equipment by model number alone. Consider the water volume, depth, fish load, filter type, pipe or airline run, and how easy the equipment will be to access for routine servicing. A correctly matched system will usually perform better, run more quietly and last longer than an oversized product connected to restrictive pipework or undersized accessories.

On larger ponds and lakes, it is often better to spread performance across the system rather than concentrating everything in one place. Air pumps can be paired with multiple diffuser stations, wave makers can be used to improve circulation in dead spots, and chillers should be installed with enough flow and ventilation to work efficiently. This approach gives a more stable pond environment and makes future maintenance much easier.

Useful installation links

Recommended circulation pump

For a straightforward dedicated installation, we recommend the Hailea HX-8830 Water Pump. Its published maximum flow is 2,900 L/h, which gives a practical starting point for this chiller’s recommended 1,000–3,000 L/h operating band.

Important: pump ratings are measured at little or no head. Hose length, lift, bends, fittings and equipment resistance reduce the actual flow. Use a bypass or control valve where required, and confirm the installed flow remains within the chiller’s stated range. Chiller selection must also allow for water volume, ambient temperature and total heat load.

Products related to the Hailea HC-2200BH Water Chiller

Hailea HC-2200BH Water Chiller Reviews

Reviews

There are no reviews yet.

Be the first to review “Hailea HC-2200BH Water Chiller”