Interpet Airvolution AV2 Aquarium Air Pump
| Brand | |
|---|---|
| Airflow | 200 L/h |
| Power | 3.5 W |
| Air outlets | 1 |
| Aquarium guide | 51–100 litres |
| Dimensions H Ă— W Ă— D | 9.6 Ă— 5.4 Ă— 14.2 cm |
Interpet Airvolution AV2 aquarium air pump: 200 L/h, a single outlet, 3.5 W and a 51–100 litres aquarium guide. Airline and airstone supplied separately.
£31.99 (inc VAT)
The Interpet Airvolution AV2 is a mains-powered aquarium air pump with a single outlet. Its stated air output is 200 L/h. Interpet gives this model a 51–100 litres aquarium guide and a 3.5 W power rating. It supplies air to a suitable airstone, air feature or air-powered filter through separate aquarium airline.
The moulded housing, inlet noise-suppression arrangement and anti-vibration feet are designed to reduce operating noise. Positioning still matters: stand the pump securely on its feet and avoid letting the tubing or case transmit vibration into surrounding furniture.
How this model compares
The AV2 is the single-outlet choice, with a stated 200 L/h air figure. The larger AV3 has twin outlets and a stated 2 Ă— 250 L/h figure, or 500 L/h combined. The actual flow at an air feature depends on tubing, water depth and resistance.
Use the 51–100 litres aquarium guide as a starting point, alongside the aquarium setup and the air-powered equipment you need to run. The air-output figures compare these models in litres per hour; delivered air depends on the installation.
Technical overview
| Model | Interpet Airvolution AV2 |
|---|---|
| Air output | 200 L/h — manufacturer manual figure |
| Air outlets | 1 |
| Power | 3.5 W |
| Aquarium guide | 51–100 litres |
| Assembled size H Ă— W Ă— D | 9.6 Ă— 5.4 Ă— 14.2 cm |
| Use | Indoor, dry-positioned air pump |
| Intake filtration | Fitted felt and carbon air-filter pads |
| Matching service parts | Maintenance kit 2547; carbon/felt pack 2549 |
| Airline and airstone | Supplied separately |
Positioning and connecting the pump
Keep the pump indoors and dry. Place it on a secure surface above the aquarium water level where possible, but not directly over the tank where it could fall in. Arrange the mains cable safely and use a drip loop. Keep electrical connections away from water and disconnect the pump before maintenance.
If the pump is below the aquarium water level, the manual calls for a suitable check valve in the airline between the pump and the aquarium, close to the pump outlet. It also recommends above-water positioning and a check valve for marine use. Choose the installation and accessories in accordance with the manufacturer’s instructions; the pump itself is not submersible.
What is included and what else is needed?
One Airvolution AV2 pump with its fitted intake filtration is supplied. Airline, airstones and a check valve are separate accessories. Choose suitable airline and an air-powered feature or filter for the job, and check the connection arrangement before installation.
Routine care and matching spares
Keep the intake filter pads clear of dust. The manufacturer’s leaflet suggests replacing the air-filter pad about every three to six months, depending on the environment in which the pump operates. Inspect the intake during routine care and disconnect the power before changing a pad.
If airflow falls, check for a blocked intake pad, kinked or leaking airline, restricted fittings and clogged airstones before assuming that the pump needs replacement. Follow the manual for any internal servicing and use the correct model-specific parts.
Interpet lists maintenance kit 2547 and carbon/felt filter pack 2549 for this model. Those spares are separate purchases. The AV3 uses the different AV3/AV4 parts 2550 and 2552.
Browse our Aquarium range for related aquarium equipment and accessories.
Frequently asked questions
Does the AV2 include airline and an airstone?
This AV2 version is supplied without airline or airstone. One pump with fitted intake filtration is supplied; connect it to suitable air-powered equipment using separate airline, with a check valve where required.
How many outlets does this pump have?
The AV2 has one direct outlet and a stated 200 L/h air-output figure. The AV3 is the larger twin-outlet model, rated in the manual at 2 Ă— 250 L/h.
Can the pump sit below the water level?
The pump must remain dry. For below-water-level positioning, the manual requires a check valve in the airline between the pump and aquarium, close to the pump outlet. Above-water positioning should still avoid placing the pump directly over the tank.
Which replacement pads and maintenance kit match this model?
Interpet lists maintenance kit 2547 and carbon/felt pack 2549 for the AV2. Match the model and part reference before ordering; these are separate servicing products.
How often should the intake pad be changed?
The manufacturer suggests approximately three to six months, depending on the operating environment. Keep an eye on dust or restriction during routine checks and disconnect the power before replacing the pad.




Reviews
There are no reviews yet.