Hanna HI98129 Low Range pH, EC and TDS Combo Tester
| Brand | |
|---|---|
| Model | HI-98129 |
| Measurements | pH, EC, calculated TDS and temperature |
| pH range | 0.00–14.00 |
| Conductivity range | 0–3,999 µS/cm |
| TDS range | 0–2,000 ppm |
| Temperature range | 0.0–60.0°C |
| pH accuracy | ±0.05 pH |
| EC/TDS accuracy | ±2% of full scale |
| TDS factor | Adjustable, 0.45–1.00 |
| Included pH electrode | HI73127, replaceable |
| pH calibration | Automatic one or two points |
| Manufacturer weight | 100 g |
The HI98129 combines pH, conductivity, calculated total dissolved solids and temperature in a water-resistant pocket instrument. It suits routine freshwater and source-water checks where the low conductivity range covers the water being measured.
Supplier dispatch: Supplied directly by Hanna Instruments. Supplier stock was shown as available at our latest check.
£281.57 (inc VAT)
Hanna HI98129 Low Range pH, EC and TDS Combo Tester
Four useful water measurements in one pocket tester
The HI98129 combines pH, conductivity, calculated total dissolved solids and temperature in a water-resistant pocket instrument. It suits routine freshwater and source-water checks where the low conductivity range covers the water being measured.
Choosing the right measurement
TDS is calculated from conductivity using the selected conversion factor; it is not a direct laboratory measurement of every dissolved substance. This low range model is not a marine salinity tester. For pH-only or EC/TDS-only work, a dedicated tester may be a simpler choice.
Technical overview
| Specification | Details |
|---|---|
| Measurements | pH, EC, calculated TDS and temperature |
| pH range | 0.00–14.00 |
| Conductivity range | 0–3,999 µS/cm |
| TDS range | 0–2,000 ppm |
| Temperature range | 0.0–60.0°C |
| pH accuracy | ±0.05 pH |
| EC/TDS accuracy | ±2% of full scale |
| TDS factor | Adjustable, 0.45–1.00 |
| Included pH electrode | HI73127, replaceable |
| pH calibration | Automatic one or two points |
| Manufacturer weight | 100 g |
What is included
- HI98129 Combo tester
- HI73127 pH electrode
- HI73128 electrode removal tool
- Batteries and instructions
Reagents and optional accessories
pH buffers, conductivity standards, electrode cleaner and storage solution are separate consumables unless expressly supplied in a selected bundle. HI1271 is not the same replacement electrode as HI73127.
Care and reliable results
Calibrate pH and conductivity with the appropriate standards and follow the care instructions for the replaceable HI73127 pH electrode. Use electrode storage solution rather than storing the glass pH sensor dry or in pure water. Its IP65 water-resistant casing is not a permission for continuous submersion.
Compare related options
Further Hanna supplies and comparisons
Matching methods and supplies
Match the exact instrument and method. These are separate products; check the supplied contents before adding another item.
- Hanna HI70004P pH 4.01 Buffer Sachets — Choose the buffer points required by the instrument calibration procedure; an optional buffer is not a promise that it is included.
- Hanna HI70007P pH 7.01 Buffer Sachets — Choose the buffer points required by the instrument calibration procedure; an optional buffer is not a promise that it is included.
- Hanna HI70010P pH 10.01 Buffer Sachets, 25 Pack — Choose the buffer points required by the instrument calibration procedure; an optional buffer is not a promise that it is included.
- Hanna HI70031P 1413µS EC Calibration Sachets — 1413 µS/cm conductivity standard; retain the method and temperature-compensation instructions. Do not substitute a different conductivity or TDS value.
- Hanna HI70032P 1382ppm TDS Calibration Sachets — Optional separately listed 1382 ppm TDS reference at CONV=0.5. It is not the TDS conversion of the 1413 µS/cm EC calibration point: that would be 706.5 ppm at factor 0.5. The exact HI98129 manual calibrates conductivity with 1413 µS/cm and states that separate TDS calibration is unnecessary; do not present this accessory reference as a required second calibration.
- Hanna HI73127 Replacement pH Electrode Cartridge — Exact replacement electrode reference; not HI1271 and not a generic probe fit.
- Hanna HI77400P pH 4.01 and 7.01 Buffer Sachets — Choose the buffer points required by the instrument calibration procedure; an optional buffer is not a promise that it is included.



Reviews