Hanna HI9147-04 Dissolved Oxygen Meter with 4 m Probe
| Brand | |
|---|---|
| Model | HI-9147-04 |
| Measurement | Dissolved oxygen and temperature |
| Oxygen range | 0.0–50.0 mg/L |
| Saturation range | 0–600% |
| Oxygen resolution | 0.1 mg/L; 1% saturation |
| Sensor type | Galvanic |
| Included probe | HI76409/4 with 4 m cable |
| Temperature range | −5.0 to 50.0°C |
The HI9147-04 is the four-metre probe package of Hanna’s galvanic dissolved oxygen meter. It measures oxygen concentration, percentage saturation and temperature, providing a portable option for pond, lake and aquaculture checks.
Supplier dispatch: Supplied directly by Hanna Instruments. Supplier stock was shown as available at our latest check.
£781.69 (inc VAT)
Hanna HI9147-04 Dissolved Oxygen Meter with 4 m Probe
A galvanic oxygen meter for fish farming and field checks
The HI9147-04 is the four-metre probe package of Hanna’s galvanic dissolved oxygen meter. It measures oxygen concentration, percentage saturation and temperature, providing a portable option for pond, lake and aquaculture checks.
Choosing the right measurement
A galvanic sensor does not require the external polarisation period associated with a polarographic oxygen probe. Preparation and a stable reading are still required. Choose the cable length for the actual access and depth needed: this four-metre package differs from the HI9147-10 supplied with a ten-metre probe.
Technical overview
| Specification | Details |
|---|---|
| Measurement | Dissolved oxygen and temperature |
| Oxygen range | 0.0–50.0 mg/L |
| Saturation range | 0–600% |
| Oxygen resolution | 0.1 mg/L; 1% saturation |
| Sensor type | Galvanic |
| Included probe | HI76409/4 with 4 m cable |
| Temperature range | −5.0 to 50.0°C |
What is included
- HI9147 meter
- HI76409/4 galvanic probe with 4 m cable
- Two spare membranes
- 30 mL electrolyte solution
- Batteries, calibration screwdriver and instructions
Reagents and optional accessories
The ten-metre HI9147-10 is a separate package. Use the exact probe, membrane and electrolyte references for the supplied HI76409/4 sensor.
Care and reliable results
The probe still needs cleaning, membrane and electrolyte care. Follow the air-calibration procedure and set the relevant water and site compensation correctly. A cable’s length is not a promise that every location or depth is suitable for a particular sampling method.
Compare related options
Further Hanna supplies and comparisons
Matching methods and supplies
Match the exact instrument and method. These are separate products; check the supplied contents before adding another item.
- Hanna HI7040L Zero Oxygen Solution, 500ml — Use only the exact instrument/probe calibration procedure; zero-oxygen solution is not a galvanic membrane or electrolyte kit.



Reviews