Evolution Aqua Nexus 220+
| Brand | |
|---|---|
| Installation | Gravity fed, Pump fed |
Evolution Aqua Nexus 220+ combines static K1 Micro mechanical filtration and an aerated K+ moving bed. Supplied with 50 litres of K+ media; manufacturer pond guidance up to 18,000 litres. Match the pump, air supply and installation to the pond.
When purchasing your Nexus filter from us, we include a genuine Evolution Aqua Nexus Lid at no additional cost.
£1,445.00 (inc VAT)
Evolution Aqua Nexus 220+
Mechanical and moving-bed filtration for koi ponds
Includes FREE Genuine Evolution Aqua Nexus Lid. Supplied at no extra cost when purchased with this filter.
The Nexus 220+ separates fine waste in its central Eazy chamber, then passes the water through an aerated moving bed for biological filtration. It suits a pond owner who wants access to both stages and is prepared to clean the mechanical section, or add the correct automatic cleaning kit.
The manufacturer gives a maximum pond-volume guideline of 18,000 litres. That is a sizing guideline, rather than a guarantee for every stocking or feeding level. We would also look at the fish load, daily feed, delivered pump flow, filter maturity and cleaning access before recommending a system.
What the two media chambers do
The central Eazy section contains 18 litres of static K1 Micro media. Waste is held here during normal filtering; air is used to agitate the media during the cleaning sequence. The waste still needs to leave the system through the drain.
The outer chamber contains 50 litres of K+ moving-bed media as supplied. Air keeps it moving during filtration and supports the bacteria that process ammonia and nitrite. These bacteria need time to establish, so test the water during maturation and after changes to feeding or fish load.
| Specification | This model |
|---|---|
| Manufacturer maximum pond guidance | 18,000 litres |
| Maximum permitted filter flow | 10,000L/h |
| K1 Micro in the Eazy section | 18 litres |
| K+ supplied / maximum media volume | 50 / 150 litres |
| Integrated UV | Not included; choose a separate UV if required |
| Cleaning automation | Optional compatible system; auto-ready does not mean a cleaning kit is included |
Plan the pump-fed or gravity-fed layout first
In a pump-fed installation, the pump sends pond water to the filter and the return flows back by gravity. In a gravity-fed system, water enters the filter from the pond and the pump follows the filter. The working water level, standpipe arrangement, base height and return route must suit the chosen layout.
Current Nexus+ instructions describe the unit as supplied for pump-fed use, with changes required for gravity-fed installation. Follow the exact manual before connecting pipework; the two layouts are not interchangeable simply by moving the pump.
Use a level base that supports the complete water-filled filter. Leave room for the lid, waste valves, unions and routine servicing. Check the current installation drawing before building the base or ordering connecting pipework.
Choose flow for this pond
The 10,000L/h figure is a maximum filter limit. It is not a universal operating target. The standard Nexus+ manuals suggest considering pond turnover over about two to three hours, while staying within the filter limit. Select the pond pump from the flow it can deliver after lift, pipework and fittings, and measure that flow once installed.
An adjustable Evolution Aqua Varipump can help set the duty, but its maximum flow alone does not prove that a particular model suits the pond. Our pump-sizing guide explains how to allow for head and friction losses.
Air supply and additional media
The Nexus 220+ manual pairs an Airtech 75 with 50–75 litres of biological media, Airtech 95 with 75–100 litres, and Airtech 130 with 100–150 litres. Use the guidance for the actual filter and media load, and check that the whole bed is moving properly once running.
Compare Airtech air pumps and additional K+ media together. A pump’s free-air rating is not a guarantee of the air delivered through the installed air line and diffuser. Confirm the required duty before substituting another air-pump model.
UV clarification and the Ti version
This standard Nexus+ model has no integrated UV. Compare the Nexus 220 Titanium if you want integrated clarification, or choose a separate Evolution Aqua evoUV around the installation. Replacement Ti lamps and lids must match the Ti revision; the standard filter’s specification does not establish those parts.
Cleaning and automatic-kit compatibility
Auto-ready fixings allow a compatible automatic cleaning system to be added. Compare the 220 gravity-fed kit with the pump-fed cleaning kit and check the filter’s age, model and UV arrangement before choosing.
Without automation, follow the manual’s isolation, air-cleaning and waste-draining sequence. With automation, continue to check the waste outlet, valve operation, water level and replacement water. Set the interval around the actual debris load rather than assuming the filter needs no further attention.
Use pond water tests while the biology establishes and whenever feeding, fish load or filter performance changes. For installation examples and a fuller comparison, read our Nexus filter guide. You can also compare the Nexus range and the wider Evolution Aqua range.
See the Nexus 220+ installation manual for the base filter, and use the separate Ti instructions where the filter has integrated UV.